Hartmannometer and Fizeau interferometer: comparative analysis of optical-surface testing devices

Subject of study. This study proposes an optomechanical device as an alternative to a Fizeau interferometer for optical-surface quality control. Aim of study. The aim of the study was to develop and assess a metrological device for measuring optical-surface flatness and to compare the measurement results obtained with this device against those from a Fizeau interferometer. Method. The wavefront of the radiation reflected from the tested optical surface is measured using a Shack–Hartmann sensor. Main results. This research developed a fundamentally new device, named a Hartmannometer. A method for its calibration is introduced, and a comparison is made between the measurements of a test optical surface using both the developed device and a conventional Fizeau interferometer. The total wavefront-distortion amplitude measured using the Fizeau interferometer was 0.127 µm (root mean square deviation of 0.022 µm), while the Hartmannometer showed a total distortion amplitude of 0.131 µm (root mean square deviation of 0.024 µm). Practical significance. The developed device may serve as a more reliable and cost-effective alternative to the Fizeau interferometer for tasks related to the quality control of optical surfaces.

Authors

Institutions

Publication Details

Journal
Journal of Optical Technology
Published
2024-11-01
DOI
https://doi.org/10.1364/jot.91.000737
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hartmannometer and Fizeau interferometer: comparative analysis of optical-surface testing devices

Alexis Kudryashov, Sausan Kh. Abdulrazak, Alexander Nikitin, Julia Sheldakova et al.
Journal of Optical Technology
Optical measurement and interference techniques
article

Hartmannometer and Fizeau interferometer: comparative analysis of optical-surface testing devices

Alexis Kudryashov, Sausan Kh. Abdulrazak, Alexander Nikitin, Julia Sheldakova, Vladimir Toporovsky, Ilya Galaktionov
article en

Abstract

Subject of study. This study proposes an optomechanical device as an alternative to a Fizeau interferometer for optical-surface quality control. Aim of study. The aim of the study was to develop and assess a metrological device for measuring optical-surface flatness and to compare the measurement results obtained with this device against those from a Fizeau interferometer. Method. The wavefront of the radiation reflected from the tested optical surface is measured using a Shack–Hartmann sensor. Main results. This research developed a fundamentally new device, named a Hartmannometer. A method for its calibration is introduced, and a comparison is made between the measurements of a test optical surface using both the developed device and a conventional Fizeau interferometer. The total wavefront-distortion amplitude measured using the Fizeau interferometer was 0.127 µm (root mean square deviation of 0.022 µm), while the Hartmannometer showed a total distortion amplitude of 0.131 µm (root mean square deviation of 0.024 µm). Practical significance. The developed device may serve as a more reliable and cost-effective alternative to the Fizeau interferometer for tasks related to the quality control of optical surfaces.

Journal of Optical TechnologyVol. 91(11)
Russian Academy of Sciences (RU), Moscow Polytechnic University (RU)
Openalex Percentile: Top 70%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.