Influence of different ambient luminances on the perception of gray values

Abstract Introduction In clinical practice, dental offices present varying ambient light conditions that may influence the assessment of radiographic exams. Objective Evaluate the influence of ambient light conditions on the contrast sensitivity function in the perception of different densities on dental radiographs. Material and method 55 conventional radiographs of aluminum step-wedges were evaluated by four previously trained and calibrated observers (two undergraduate students and two graduate students) in two environments with different luminance: 50 lux and 500 lux. The radiographs were obtained by positioning two aluminum step-wedges (one fragmented and one intact) with 11 different thicknesses in a periapical film. The fragmented steps were randomly arranged on the upper side of a periapical film while the intact step-wedge was positioned on the bottom part. Over the radiographic series, this arrangement was set respecting a previously standardized organization in five combinations, always maintaining a constant central step. During image analysis, the observers indicated the correspondence of the central fragmented step on the intact step-wedge that served as a reference. After 30 days, 25% of the sample was reevaluated. The statistical analysis was performed using weighted Kappa and Wilcoxon tests. Result The results did not demonstrate statistically significant differences between the data obtained in the same environment with the two different light conditions (p=0.174). However, in both conditions, most evaluations indicated a perception of higher radiopacity in the central step. Conclusion Different ambient light conditions do not interfere with the contrast sensitivity function in the perception of gray values in conventional radiographs.

Authors

Institutions

Publication Details

Journal
Revista de Odontologia da UNESP
Published
2025-01-01
DOI
https://doi.org/10.1590/1807-2577.00425
Primary Topic
Color perception and design
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of different ambient luminances on the perception of gray values

Francielle Silvestre Verner, Gabriella Lopes de Rezende Barbosa, Camila Silvério Carvalho Vieira, Lorena Mendes Almeida
Revista de Odontologia da UNESP
Color perception and design
article

Influence of different ambient luminances on the perception of gray values

Francielle Silvestre Verner, Gabriella Lopes de Rezende Barbosa, Camila Silvério Carvalho Vieira, Lorena Mendes Almeida
article en

Abstract

Abstract Introduction In clinical practice, dental offices present varying ambient light conditions that may influence the assessment of radiographic exams. Objective Evaluate the influence of ambient light conditions on the contrast sensitivity function in the perception of different densities on dental radiographs. Material and method 55 conventional radiographs of aluminum step-wedges were evaluated by four previously trained and calibrated observers (two undergraduate students and two graduate students) in two environments with different luminance: 50 lux and 500 lux. The radiographs were obtained by positioning two aluminum step-wedges (one fragmented and one intact) with 11 different thicknesses in a periapical film. The fragmented steps were randomly arranged on the upper side of a periapical film while the intact step-wedge was positioned on the bottom part. Over the radiographic series, this arrangement was set respecting a previously standardized organization in five combinations, always maintaining a constant central step. During image analysis, the observers indicated the correspondence of the central fragmented step on the intact step-wedge that served as a reference. After 30 days, 25% of the sample was reevaluated. The statistical analysis was performed using weighted Kappa and Wilcoxon tests. Result The results did not demonstrate statistically significant differences between the data obtained in the same environment with the two different light conditions (p=0.174). However, in both conditions, most evaluations indicated a perception of higher radiopacity in the central step. Conclusion Different ambient light conditions do not interfere with the contrast sensitivity function in the perception of gray values in conventional radiographs.

Revista de Odontologia da UNESPVol. 54
Universidade Federal de Juiz de Fora (BR), Universidade Federal de Uberlândia (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de Minas Gerais
Openalex Percentile: Top 86%
Color perception and design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.