A Fluorescent Aptamer Sensor for Detecting Golgi Protein 73 Based on Magnetic Ferroferric Oxide@Boron, Nitrogen‐Doped Graphene Quantum Dots

In this paper, a fluorescent aptamer sensor based on magnetic ferroferric oxide@boron, nitrogen-doped graphene quantum dots (Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs) was developed to detect Golgi protein 73 (GP73). GP73 aptamer (GP73<sub>Apt</sub>) functioned with Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs (Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub>) and was used as the fluorescent donor, while molybdenum disulfide (MoS<sub>2</sub>) with a large surface served as the fluorescent acceptor. The fluorescence of Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub> was quenched by MoS<sub>2</sub> based on the fluorescence resonance energy transfer (FRET) principle. However, in the presence of GP73, Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub> could specifically bind to GP73, forming a Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub>-GP73 complex. This binding event caused Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub> to move away from the surface of MoS<sub>2</sub>, thus blocking the FRET process and recovering the fluorescence. Under optimal conditions, a linear relationship was established between the fluorescence recovery and the concentration of GP73 within the range of 10-1000 ng/mL (R<sup>2 </sup>= 0.9918), and the limit of detection was 7.37 ng/mL. Additionally, when the sensor was applied to test actual samples, the recovery rates were in the range of 98.80%-101.18%, and the relative standard deviations were between 0.29%-3.04%. These findings demonstrated the excellent detection performance of the proposed fluorescent aptamer sensor.

Authors

Institutions

Publication Details

Journal
Biotechnology and Applied Biochemistry
Published
2025-06-08
DOI
https://doi.org/10.1002/bab.70006
Primary Topic
Carbon and Quantum Dots Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fluorescent Aptamer Sensor for Detecting Golgi Protein 73 Based on Magnetic Ferroferric Oxide@Boron, Nitrogen‐Doped Graphene Quantum Dots

Yong Huang, Ruijie Yan, He Wei, Xiaodong Su et al.
Biotechnology and Applied Biochemistry
Carbon and Quantum Dots Applications
article

A Fluorescent Aptamer Sensor for Detecting Golgi Protein 73 Based on Magnetic Ferroferric Oxide@Boron, Nitrogen‐Doped Graphene Quantum Dots

Yong Huang, Ruijie Yan, He Wei, Xiaodong Su, Tingting Yu, Guiyin Li, Xiaohong Tan
article en

Abstract

In this paper, a fluorescent aptamer sensor based on magnetic ferroferric oxide@boron, nitrogen-doped graphene quantum dots (Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs) was developed to detect Golgi protein 73 (GP73). GP73 aptamer (GP73<sub>Apt</sub>) functioned with Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs (Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub>) and was used as the fluorescent donor, while molybdenum disulfide (MoS<sub>2</sub>) with a large surface served as the fluorescent acceptor. The fluorescence of Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub> was quenched by MoS<sub>2</sub> based on the fluorescence resonance energy transfer (FRET) principle. However, in the presence of GP73, Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub> could specifically bind to GP73, forming a Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub>-GP73 complex. This binding event caused Fe<sub>3</sub>O<sub>4</sub>@B,N-GQDs-GP73<sub>Apt</sub> to move away from the surface of MoS<sub>2</sub>, thus blocking the FRET process and recovering the fluorescence. Under optimal conditions, a linear relationship was established between the fluorescence recovery and the concentration of GP73 within the range of 10-1000 ng/mL (R<sup>2 </sup>= 0.9918), and the limit of detection was 7.37 ng/mL. Additionally, when the sensor was applied to test actual samples, the recovery rates were in the range of 98.80%-101.18%, and the relative standard deviations were between 0.29%-3.04%. These findings demonstrated the excellent detection performance of the proposed fluorescent aptamer sensor.

Biotechnology and Applied BiochemistryVol. 73(1)
Guangxi Medical University (CN), Theranostics (New Zealand) (NZ), Guangdong University of Petrochemical Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 91%
Carbon and Quantum Dots Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.