Influence of dose rate changes on beam alignment in medical linear accelerators

Abstract Introduction: The technological development of radiotherapy equipment enabled the changing of the dose rate over time during irradiation. Further, techniques, such as volumetric modulated arc therapy (VMAT), are becoming more widespread. This study aimed to assess the changes in radiation isocenter and beam alignment with different dose rates and investigate the dose error during VMAT plan delivery. Method: The Winston–Lutz (WL) test and three-dimensional water phantom profiles were measured at different dose rates using 4, 6 and 10 MV and flattening filter-free (FFF) at 6 and 10 MV of X-rays. Furthermore, the change in alignment with the dose rate was reproduced through beam parameter adjustments, and the change in dose difference (DD) in the VMAT plan was assessed. Results: The WL test revealed a 0·1–0·3 mm radiation isocenter displacement with dose rate. Further, the beam profile measurement results demonstrated a 0·3 mm beam centre position displacement in both the lateral and gun-target directions caused by the change in dose rate. VMAT plan delivery with a beam whose centre position changed by 0·3 mm caused a 0·2–3% decrease in the previous DD rate. Conclusion: The radiation isocenter and beam alignment changed based on the dose rate. Evaluating the change in beam alignment at multiple dose rates is recommended when performing irradiation with different dose rates.

Authors

Institutions

Publication Details

Journal
Journal of Radiotherapy in Practice
Published
2025-01-01
DOI
https://doi.org/10.1017/s1460396925000196
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of dose rate changes on beam alignment in medical linear accelerators

Masahiro Fukushi, Yutaro Mori, Takeji Sakae, Tomonori Isobe et al.
Journal of Radiotherapy in Practice
Advanced Radiotherapy Techniques
article

Influence of dose rate changes on beam alignment in medical linear accelerators

Masahiro Fukushi, Yutaro Mori, Takeji Sakae, Tomonori Isobe, Yoshiaki Nagai, Tetsuya Tomita
article en

Abstract

Abstract Introduction: The technological development of radiotherapy equipment enabled the changing of the dose rate over time during irradiation. Further, techniques, such as volumetric modulated arc therapy (VMAT), are becoming more widespread. This study aimed to assess the changes in radiation isocenter and beam alignment with different dose rates and investigate the dose error during VMAT plan delivery. Method: The Winston–Lutz (WL) test and three-dimensional water phantom profiles were measured at different dose rates using 4, 6 and 10 MV and flattening filter-free (FFF) at 6 and 10 MV of X-rays. Furthermore, the change in alignment with the dose rate was reproduced through beam parameter adjustments, and the change in dose difference (DD) in the VMAT plan was assessed. Results: The WL test revealed a 0·1–0·3 mm radiation isocenter displacement with dose rate. Further, the beam profile measurement results demonstrated a 0·3 mm beam centre position displacement in both the lateral and gun-target directions caused by the change in dose rate. VMAT plan delivery with a beam whose centre position changed by 0·3 mm caused a 0·2–3% decrease in the previous DD rate. Conclusion: The radiation isocenter and beam alignment changed based on the dose rate. Evaluating the change in beam alignment at multiple dose rates is recommended when performing irradiation with different dose rates.

Journal of Radiotherapy in PracticeVol. 24
University of Tsukuba (JP), University of Tsukuba Hospital (JP), Tsukuba International University (JP)
Jichi Medical University
Openalex Percentile: Top 81%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of dose rate changes on beam alignment in medical linear accelerators — Masahiro Fukushi, Yutaro Mori, et al. · Journal of Radiotherapy in Practice (2025) | TGRS Research Map | TGRS