Personalized Contrast Agent Volumes in Abdominal CT: Bridging Theory with Practice

<i>Objectives:</i> to determine (1) a target Hounsfield unit (HU) for portal venous phase iodinated contrast media enhanced abdominal CT scans, (2) an equation for a personalized total contrast agent volume, and (3) the best/most appropriate time between injection and plateau/peak in HU enhancement. <i>Material and methods:</i> from an original dataset of 5,000 cases, a weight representative subset of 370 cases was sampled for detailed HU measurements. An additional 90 cases were used for visual grading to define the minimal HU required for diagnostic quality, which led to the proposed target HU. This study uses the fact that in a first approach, the injected contrast agent volume and HU correlate linearly. Based on the injected contrast agent volumes and HU measurements in the patient scans, it was then calculated which (ideal) volume would have reached the target value. The ideal volumes and patient data (weight, height, heart rate, age, and gender) were correlated by means of a regression analysis, to determine a new patient-specific contrast volume calculation equation. The best scan delay time was derived from the start of the injection to the HU enhancement plateau/peak evaluated from manually triggered venous phase scans. <i>Results:</i> The target HU value was 125. This can be achieved with a personalized contrast agent volume (ml), equal to - 108.5 + ∗ <i>weight(kg)</i> + 0.40 ∗ <i>heart rate(bpm)</i> + 0.61 ∗ <i>height(cm)</i>. The time delay between injection and HU plateau/peak was found to be, on average, 102 s. <i>Conclusion:</i> this study proposes a comprehensive protocol for contrast enhanced venous phase scans, including a target HU, a personalized contrast volume, and a scan delay.

Authors

Institutions

Publication Details

Journal
Journal of the Belgian Society of Radiology
Published
2025-01-01
DOI
https://doi.org/10.5334/jbsr.3906
Citations
2
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Personalized Contrast Agent Volumes in Abdominal CT: Bridging Theory with Practice

Didier Bielen, Walter Coudyzer, Lesley Cockmartin, Hilde Bosmans et al.
2 citations
Journal of the Belgian Society of Radiology
Advanced X-ray and CT Imaging
1.35
article

Personalized Contrast Agent Volumes in Abdominal CT: Bridging Theory with Practice

Didier Bielen, Walter Coudyzer, Lesley Cockmartin, Hilde Bosmans, Dirk Vanbeckevoort, R. Øyen, Bram Miseur, Tim Busselot
article en
2 citations

Abstract

<i>Objectives:</i> to determine (1) a target Hounsfield unit (HU) for portal venous phase iodinated contrast media enhanced abdominal CT scans, (2) an equation for a personalized total contrast agent volume, and (3) the best/most appropriate time between injection and plateau/peak in HU enhancement. <i>Material and methods:</i> from an original dataset of 5,000 cases, a weight representative subset of 370 cases was sampled for detailed HU measurements. An additional 90 cases were used for visual grading to define the minimal HU required for diagnostic quality, which led to the proposed target HU. This study uses the fact that in a first approach, the injected contrast agent volume and HU correlate linearly. Based on the injected contrast agent volumes and HU measurements in the patient scans, it was then calculated which (ideal) volume would have reached the target value. The ideal volumes and patient data (weight, height, heart rate, age, and gender) were correlated by means of a regression analysis, to determine a new patient-specific contrast volume calculation equation. The best scan delay time was derived from the start of the injection to the HU enhancement plateau/peak evaluated from manually triggered venous phase scans. <i>Results:</i> The target HU value was 125. This can be achieved with a personalized contrast agent volume (ml), equal to - 108.5 + ∗ <i>weight(kg)</i> + 0.40 ∗ <i>heart rate(bpm)</i> + 0.61 ∗ <i>height(cm)</i>. The time delay between injection and HU plateau/peak was found to be, on average, 102 s. <i>Conclusion:</i> this study proposes a comprehensive protocol for contrast enhanced venous phase scans, including a target HU, a personalized contrast volume, and a scan delay.

Journal of the Belgian Society of RadiologyVol. 109(1)
KU Leuven (BE)
Gender equality
Openalex Percentile: Top 19%
Advanced X-ray and CT Imaging
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.