Investigation and Improvement of Inconsistency in Surface-Form Measurement Results Due to Difference of Incident Direction of Measuring Light in Abramson-Type Oblique-Incident Interferometer

An Abramson-type oblique-incident interferometer was used for the surface-form measurement of hand-scraped marks consisting of rough surfaces. Although the Abramson interferometer could measure the rough surface of hand-scraped marks under noncontact conditions, the inconsistency in the measurement results was caused by the differences in the incident direction of the measuring light. This study investigated the inconsistency in the measurement results of the Abramson interferometer caused by the oblique incidence of the measuring light. The reproducibility of inconsistencies due to the difference in the incident direction of the measuring light was confirmed, and the relationship between the inconsistency of the measurement results and the incident angle of the measuring light was investigated. Consequently, it was confirmed that the inconsistency of the measurement results due to the difference in the incident direction of the measuring light could be reduced by decreasing the incident angle of the measuring light. To avoid the overcrowding of the interference fringes caused by the reduction in the incident angle of the measuring light, an oblique-incident interferometer with a near-infrared laser was constructed. The validity of the developed oblique-incident interferometer was evaluated by comparison with a commercially available contour measurement instrument. The surface form obtained by the developed oblique-incident interferometer was confirmed to be consistent with the envelope of the cross-sectional profile measured by the contour measurement instrument.

Authors

Institutions

Publication Details

Journal
Metrology
Published
2025-06-07
DOI
https://doi.org/10.3390/metrology5020034
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation and Improvement of Inconsistency in Surface-Form Measurement Results Due to Difference of Incident Direction of Measuring Light in Abramson-Type Oblique-Incident Interferometer

Kazuhide Kamiya, Takeshi Yamagishi, Kimihisa Matsumoto, Shota Ito
Metrology
Optical measurement and interference techniques
article

Investigation and Improvement of Inconsistency in Surface-Form Measurement Results Due to Difference of Incident Direction of Measuring Light in Abramson-Type Oblique-Incident Interferometer

Kazuhide Kamiya, Takeshi Yamagishi, Kimihisa Matsumoto, Shota Ito
article en

Abstract

An Abramson-type oblique-incident interferometer was used for the surface-form measurement of hand-scraped marks consisting of rough surfaces. Although the Abramson interferometer could measure the rough surface of hand-scraped marks under noncontact conditions, the inconsistency in the measurement results was caused by the differences in the incident direction of the measuring light. This study investigated the inconsistency in the measurement results of the Abramson interferometer caused by the oblique incidence of the measuring light. The reproducibility of inconsistencies due to the difference in the incident direction of the measuring light was confirmed, and the relationship between the inconsistency of the measurement results and the incident angle of the measuring light was investigated. Consequently, it was confirmed that the inconsistency of the measurement results due to the difference in the incident direction of the measuring light could be reduced by decreasing the incident angle of the measuring light. To avoid the overcrowding of the interference fringes caused by the reduction in the incident angle of the measuring light, an oblique-incident interferometer with a near-infrared laser was constructed. The validity of the developed oblique-incident interferometer was evaluated by comparison with a commercially available contour measurement instrument. The surface form obtained by the developed oblique-incident interferometer was confirmed to be consistent with the envelope of the cross-sectional profile measured by the contour measurement instrument.

MetrologyVol. 5(2)
Toyama Prefectural University (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 89%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.