Modelling Near‐Field Aerosol Exposure for Respiratory Infection Risk Assessment

Quantitative microbiological risk assessment (QMRA) is a method to estimate the risk of infectious disease transmission from human exposure to pathogens. QMRA is a helpful tool to inform health policies to control the impact of infectious disease transmission from human‐to‐human transmissible infectious respiratory diseases. QMRA combines an estimate of pathogen exposure with information on the probability of infection given the dose. The infection risk of respiratory diseases is generally assumed to depend on the interpersonal distance between the infectious person (index) and the exposed recipient. To account for close‐proximity exposure in QMRA, specific generic models are required. To be helpful in policy information, these models should be sufficiently accurate in describing elevated air concentrations of pathogens near the index. On the other hand, they should be sufficiently generic and flexible to be applied in generalized situations without requiring very specific and detailed situational information. In this work, we identified different models to account for near‐field exposure in the literature: multizone, diffusion, and jet models. These methods were tested with respect to their applicability in QMRA. We evaluated them on the criteria of ease of use, the availability of parameter values for generic application, and their ability to describe air concentrations in realistic situations as replicated in experiments. It was found that only diffusion modelling appeared to be both flexible enough to describe experimental data and to be supported by sufficient information to allow for parametrization in a wide variety of situations. The multizone models were found to be easy to use but difficult to parametrize given the arbitrariness of aspects of the modelling method. The jet models were found to be more complex to implement and adapt to specific exposure scenarios.

Authors

Institutions

Publication Details

Journal
Indoor Air
Published
2025-01-01
DOI
https://doi.org/10.1155/ina/5571740
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modelling Near‐Field Aerosol Exposure for Respiratory Infection Risk Assessment

Jack Schijven, Christiaan Delmaar, Lucie C. Vermeulen
Indoor Air
Infection Control and Ventilation
article

Modelling Near‐Field Aerosol Exposure for Respiratory Infection Risk Assessment

Jack Schijven, Christiaan Delmaar, Lucie C. Vermeulen
article en

Abstract

Quantitative microbiological risk assessment (QMRA) is a method to estimate the risk of infectious disease transmission from human exposure to pathogens. QMRA is a helpful tool to inform health policies to control the impact of infectious disease transmission from human‐to‐human transmissible infectious respiratory diseases. QMRA combines an estimate of pathogen exposure with information on the probability of infection given the dose. The infection risk of respiratory diseases is generally assumed to depend on the interpersonal distance between the infectious person (index) and the exposed recipient. To account for close‐proximity exposure in QMRA, specific generic models are required. To be helpful in policy information, these models should be sufficiently accurate in describing elevated air concentrations of pathogens near the index. On the other hand, they should be sufficiently generic and flexible to be applied in generalized situations without requiring very specific and detailed situational information. In this work, we identified different models to account for near‐field exposure in the literature: multizone, diffusion, and jet models. These methods were tested with respect to their applicability in QMRA. We evaluated them on the criteria of ease of use, the availability of parameter values for generic application, and their ability to describe air concentrations in realistic situations as replicated in experiments. It was found that only diffusion modelling appeared to be both flexible enough to describe experimental data and to be supported by sufficient information to allow for parametrization in a wide variety of situations. The multizone models were found to be easy to use but difficult to parametrize given the arbitrariness of aspects of the modelling method. The jet models were found to be more complex to implement and adapt to specific exposure scenarios.

Indoor AirVol. 2025(1)
University of Applied Sciences Utrecht (NL), Utrecht University (NL), National Institute for Public Health and the Environment (NL)
Openalex Percentile: Top 78%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.