Diagnostic Reference Levels for Radiology Examination Using General Purpose X Ray Radiography

The local DRL for Dr. Moewardi Hospital is used as a control of patient radiation safety and to measure the quality of radiological examinations conducted at the Radiology Installation of Dr. Moewardi Hospital. The study conducted an assessment on a conventional examination with a General Radiography X-ray plane. The research methodology used was a quantitative approach by using a sample of 30 patients in each examination. X-ray machine data collection was conducted by looking for the Entrance Surface Air Kerma (ESAK) equation, then inputting the patients' data of kV, mAs, FSD, and BSF into the ESAK equation to obtain Entrance Surface Dose (ESD) value of each patient. From ESD data, DRLs were made for each examination using the 3rd quartile data. The results of the study indicated that the local DRL of Dr. Moewardi Hospital was lower than the National DRL of BAPETEN

Authors

Institutions

Publication Details

Journal
Indonesian Basic and Experimental Health Sciences
Published
2025-04-29
DOI
https://doi.org/10.11594/ibehs.vol13iss2pp48-51
Primary Topic
Radiology practices and education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Reference Levels for Radiology Examination Using General Purpose X Ray Radiography

Mariyatun Mariyatun, Alviana Hapsari Purbarani, Tri Asih Widiani, Umi Umaimah
Indonesian Basic and Experimental Health Sciences
Radiology practices and education
article

Diagnostic Reference Levels for Radiology Examination Using General Purpose X Ray Radiography

Mariyatun Mariyatun, Alviana Hapsari Purbarani, Tri Asih Widiani, Umi Umaimah
article en

Abstract

The local DRL for Dr. Moewardi Hospital is used as a control of patient radiation safety and to measure the quality of radiological examinations conducted at the Radiology Installation of Dr. Moewardi Hospital. The study conducted an assessment on a conventional examination with a General Radiography X-ray plane. The research methodology used was a quantitative approach by using a sample of 30 patients in each examination. X-ray machine data collection was conducted by looking for the Entrance Surface Air Kerma (ESAK) equation, then inputting the patients' data of kV, mAs, FSD, and BSF into the ESAK equation to obtain Entrance Surface Dose (ESD) value of each patient. From ESD data, DRLs were made for each examination using the 3rd quartile data. The results of the study indicated that the local DRL of Dr. Moewardi Hospital was lower than the National DRL of BAPETEN

Indonesian Basic and Experimental Health SciencesVol. 13(2)
Broward Health (US)
Openalex Percentile: Top 80%
Radiology practices and education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Diagnostic Reference Levels for Radiology Examination Using General Purpose X Ray Radiography — Mariyatun Mariyatun, Alviana Hapsari Purbarani, et al. · Indonesian Basic and Experimental Health Sciences (2025) | TGRS Research Map | TGRS