Development of a Thiol–ene Microfluidic Chip for Hydrogen/Deuterium Exchange Mass Spectrometry (HDX-MS)

Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is a powerful technique for analyzing the conformational dynamics of proteins. Using liquid chromatography coupled to mass spectrometry (LC-MS), the method achieves high sensitivity and the option to measure the HDX either of the intact protein (global analysis) or of small peptide segments of the protein (local analysis) after online pepsin proteolysis. However, HDX-MS is currently limited by the significant cost of the specialized refrigerated UPLC-based chromatographic equipment needed and by the loss of deuterium label from the analyzed protein (30-50%), which still occurs despite cooling parts of the LC-MS system to 0 °C. Here we describe the development of a microfluidic chip (<i>HDXchip</i>) for global or local HDX-MS analysis that can be cooled to subzero temperatures. <i>HDXchip</i> comprises a sample loading module with an immobilized enzyme microreactor (IMER) for on-chip pepsin proteolysis and a module packed with reversed-phase material for on-chip desalting and reversed-phase chromatography. The chip thus integrates the hallmarks of the classical HDX-MS workflow in a low-cost, low-volume microfluidic format. Furthermore, the small size of the chip allows for efficient localized cooling of parts of the chip to subzero temperatures by a Peltier module. We show that <i>HDXchip</i> allows for HDX-MS analysis of model peptides and intact proteins at significantly lowered back-exchange compared to a conventional commercially available UPLC-based HDX-MS setup. Furthermore, we show that the chip is capable of local HDX-MS analysis of hemoglobin with good sensitivity, sequence coverage, repeatability, and low back-exchange. Our results demonstrate the potential of integrating the HDX-MS workflow, including proteolysis and separation, with subzero temperature cooling, on a microchip.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-06-09
DOI
https://doi.org/10.1021/acs.analchem.4c06230
Citations
3
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Thiol–ene Microfluidic Chip for Hydrogen/Deuterium Exchange Mass Spectrometry (HDX-MS)

Jörg P. Kutter, Jordan T. Aerts, Rasmus R. Svejdal, M. Hamidi et al.
3 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
2.27
article

Development of a Thiol–ene Microfluidic Chip for Hydrogen/Deuterium Exchange Mass Spectrometry (HDX-MS)

Jörg P. Kutter, Jordan T. Aerts, Rasmus R. Svejdal, M. Hamidi, Kasper D. Rand, Drago Sticker, A. Hansen, Vanessa B. P. Stahlhut, Daria Harmash
article en
3 citations

Abstract

Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is a powerful technique for analyzing the conformational dynamics of proteins. Using liquid chromatography coupled to mass spectrometry (LC-MS), the method achieves high sensitivity and the option to measure the HDX either of the intact protein (global analysis) or of small peptide segments of the protein (local analysis) after online pepsin proteolysis. However, HDX-MS is currently limited by the significant cost of the specialized refrigerated UPLC-based chromatographic equipment needed and by the loss of deuterium label from the analyzed protein (30-50%), which still occurs despite cooling parts of the LC-MS system to 0 °C. Here we describe the development of a microfluidic chip (<i>HDXchip</i>) for global or local HDX-MS analysis that can be cooled to subzero temperatures. <i>HDXchip</i> comprises a sample loading module with an immobilized enzyme microreactor (IMER) for on-chip pepsin proteolysis and a module packed with reversed-phase material for on-chip desalting and reversed-phase chromatography. The chip thus integrates the hallmarks of the classical HDX-MS workflow in a low-cost, low-volume microfluidic format. Furthermore, the small size of the chip allows for efficient localized cooling of parts of the chip to subzero temperatures by a Peltier module. We show that <i>HDXchip</i> allows for HDX-MS analysis of model peptides and intact proteins at significantly lowered back-exchange compared to a conventional commercially available UPLC-based HDX-MS setup. Furthermore, we show that the chip is capable of local HDX-MS analysis of hemoglobin with good sensitivity, sequence coverage, repeatability, and low back-exchange. Our results demonstrate the potential of integrating the HDX-MS workflow, including proteolysis and separation, with subzero temperature cooling, on a microchip.

Analytical ChemistryVol. 97(24)
University of Copenhagen (DK), Analysis Group (United States) (US)
Danmarks Frie Forskningsfond, European Research Council
Affordable and clean energy
Openalex Percentile: Top 12%
Mass Spectrometry Techniques and Applications
2.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.