Application of machine learning algorithms in predicting indoor residential PM2.5 concentrations

Recently Machine Learning (ML) has been amply used in environmental research for prediction purposes, but only a limited number of studies have been employed to predict indoor residential fine particulate matter, PM 2.5 concentrations. PM 2.5 can penetrate deep into the lungs and has been linked to respiratory and cardiovascular problems, with long term exposure associated with increased morbidity and mortality. The use of ML can provide a better estimate of residential PM 2.5 concentrations which usually is a significant contributor to personal exposure, especially for the elderly and those with pre-existing health conditions who tend to spend most of their time inside their homes. This study used ML algorithms (General Linear Model (GLM) with Lasso regularisation and Tree-based algorithms, RF and XGBoost) to predict indoor PM 2.5 concentrations at six-hourly averages in the Maltese Islands using outdoor residential PM concentrations and several meteorological parameters. Continuous PM sampling using aerosol spectrometers was carried out at six non-smoking residences in Malta and Gozo. A repeated 10-fold cross-validation was carried out on the training dataset, with hyperparameter tuning using grid search. Hyperparameter tuning used the Root Mean Square Error (RMSE) as the evaluation metric. Five sampling sites showed low indoor PM contributions and the GLM for these sites showed good performance indicators for the testing data, but serial correlation at lag-1 was recorded. For these sites, RF and XGBoost showed very good performance indicators with an Index of Agreement (IOA) of 0.92 and 0.93, respectively, with the most important predictor variable being the outdoor PM 1 fraction. The RF regression model gave the lowest RMSE (30.65 μg m −3 ) and the highest index of agreement (IOA) (0.66) when the models were tested with the data from all sampling sites, which included a site with a PM 2.5 I/O ratio of 5.2, where the high indoor PM generation was primarily associated with emissions from cooking and the indoor relative humidity was suggested as a good predictor variable for such a scenario. This study showed the significant impact of outdoor PM 1 on indoor PM 2.5 levels at sites with limited indoor fine PM sources. At sites with significant indoor generation from cooking, indoor PM 2.5 was 3.6 times the short-term (24-hour) AQG of the WHO, indicating that regulations on extraction systems for domestic kitchens would minimise very high exposures of home dwellers to indoor fine PM. • Indoor PM 2.5 depends on outdoor PM 1 in low indoor PM 2.5 generation sites. • GLM model showed serial correlation at lag-1. • RF model gave the lowest RMSE, 3.87 μg m −3 , when tested across five sites. • High indoor PM 2.5 in one apartment was mainly from cooking activities. • RF model used indoor RH effectively to predict high PM 2.5 in an apartment.

Authors

Institutions

Publication Details

Journal
Atmospheric Pollution Research
Published
2025-06-09
DOI
https://doi.org/10.1016/j.apr.2025.102609
Citations
1
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of machine learning algorithms in predicting indoor residential PM2.5 concentrations

Renato Camilleri, Roy M. Harrison, Noel J. Aquilina
1 citations
Atmospheric Pollution Research
Air Quality Monitoring and Forecasting
0.80
article

Application of machine learning algorithms in predicting indoor residential PM2.5 concentrations

Renato Camilleri, Roy M. Harrison, Noel J. Aquilina
article en
1 citations

Abstract

Recently Machine Learning (ML) has been amply used in environmental research for prediction purposes, but only a limited number of studies have been employed to predict indoor residential fine particulate matter, PM 2.5 concentrations. PM 2.5 can penetrate deep into the lungs and has been linked to respiratory and cardiovascular problems, with long term exposure associated with increased morbidity and mortality. The use of ML can provide a better estimate of residential PM 2.5 concentrations which usually is a significant contributor to personal exposure, especially for the elderly and those with pre-existing health conditions who tend to spend most of their time inside their homes. This study used ML algorithms (General Linear Model (GLM) with Lasso regularisation and Tree-based algorithms, RF and XGBoost) to predict indoor PM 2.5 concentrations at six-hourly averages in the Maltese Islands using outdoor residential PM concentrations and several meteorological parameters. Continuous PM sampling using aerosol spectrometers was carried out at six non-smoking residences in Malta and Gozo. A repeated 10-fold cross-validation was carried out on the training dataset, with hyperparameter tuning using grid search. Hyperparameter tuning used the Root Mean Square Error (RMSE) as the evaluation metric. Five sampling sites showed low indoor PM contributions and the GLM for these sites showed good performance indicators for the testing data, but serial correlation at lag-1 was recorded. For these sites, RF and XGBoost showed very good performance indicators with an Index of Agreement (IOA) of 0.92 and 0.93, respectively, with the most important predictor variable being the outdoor PM 1 fraction. The RF regression model gave the lowest RMSE (30.65 μg m −3 ) and the highest index of agreement (IOA) (0.66) when the models were tested with the data from all sampling sites, which included a site with a PM 2.5 I/O ratio of 5.2, where the high indoor PM generation was primarily associated with emissions from cooking and the indoor relative humidity was suggested as a good predictor variable for such a scenario. This study showed the significant impact of outdoor PM 1 on indoor PM 2.5 levels at sites with limited indoor fine PM sources. At sites with significant indoor generation from cooking, indoor PM 2.5 was 3.6 times the short-term (24-hour) AQG of the WHO, indicating that regulations on extraction systems for domestic kitchens would minimise very high exposures of home dwellers to indoor fine PM. • Indoor PM 2.5 depends on outdoor PM 1 in low indoor PM 2.5 generation sites. • GLM model showed serial correlation at lag-1. • RF model gave the lowest RMSE, 3.87 μg m −3 , when tested across five sites. • High indoor PM 2.5 in one apartment was mainly from cooking activities. • RF model used indoor RH effectively to predict high PM 2.5 in an apartment.

Atmospheric Pollution ResearchVol. 16(10)
King Abdulaziz University (SA), University of Malta (MT), National Centre for Atmospheric Science (GB), University of Birmingham (GB)
Soochow University, Università ta' Malta
Sustainable cities and communities
Openalex Percentile: Top 29%
Air Quality Monitoring and Forecasting
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.