Design and Validation of a Recirculating Cooling System for Robotic Cardiac Injection Therapy to Improve Patient Safety and Surgeon Workflow

HeartLander is a miniature mobile robot designed to navigate on the surface of the heart using a crawling motion and is well-suited for delivering myocardial injections. Previous work has incorporated a cooling system to enable delivery of a thermally responsive anti-ventricular remodeling hydrogel to a target injection site. However, the previous setup required the saline coolant to be discharged at the distal end of the system and into the patient's pericardial space, hindering the hydrogel from forming a deposit at the target site, presenting an additional burden to the surgeon's workflow, and increasing the risk to the patient. To prevent this, we redesigned the system to include a return channel for the coolant, which discharges to a reservoir outside the patient. We validated this design with a multiphysics simulation, static water bath tests, and by demonstration of controlled injections in an ovine heart ex vivo at 37°C.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2025-06-09
DOI
https://doi.org/10.1115/1.4068896
Primary Topic
Cardiac and Coronary Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Validation of a Recirculating Cooling System for Robotic Cardiac Injection Therapy to Improve Patient Safety and Surgeon Workflow

William R. Wagner, Johannes Bonatti, Cameron N. Riviere, Miguel Martinez et al.
Journal of Medical Devices
Cardiac and Coronary Surgery Techniques
article

Design and Validation of a Recirculating Cooling System for Robotic Cardiac Injection Therapy to Improve Patient Safety and Surgeon Workflow

William R. Wagner, Johannes Bonatti, Cameron N. Riviere, Miguel Martinez, Seungil Kim
article en

Abstract

HeartLander is a miniature mobile robot designed to navigate on the surface of the heart using a crawling motion and is well-suited for delivering myocardial injections. Previous work has incorporated a cooling system to enable delivery of a thermally responsive anti-ventricular remodeling hydrogel to a target injection site. However, the previous setup required the saline coolant to be discharged at the distal end of the system and into the patient's pericardial space, hindering the hydrogel from forming a deposit at the target site, presenting an additional burden to the surgeon's workflow, and increasing the risk to the patient. To prevent this, we redesigned the system to include a return channel for the coolant, which discharges to a reservoir outside the patient. We validated this design with a multiphysics simulation, static water bath tests, and by demonstration of controlled injections in an ovine heart ex vivo at 37°C.

Journal of Medical DevicesVol. 19(4)
University of Pittsburgh (US), University of Pittsburgh Medical Center (US), Carnegie Mellon University (US), Mississippi State University (US)
National Heart, Lung, and Blood Institute
Openalex Percentile: Top 77%
Cardiac and Coronary Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.