Combining Ultrasound-Assisted Extraction and ICP-MS for As, Cd, Cr, and Pb Determination in Atmospheric Particulate Matter

A simple, fast, and efficient ultrasound-assisted extraction (UAE) method for As, Cd, Cr, and Pb determination in atmospheric particulate matter (PM) by inductively coupled plasma mass spectrometry (ICP-MS) was developed. For the extraction procedure, the samples and the extraction solution were added directly into polypropylene vessels and placed in the ultrasound (US) bath. The following parameters were evaluated: i) sample mass: 50 to 500 mg, ii) extraction solutions: HNO3, HCl, and HF, and iii) extraction time in the US bath: 10 to 30 min (80 °C). Accuracy was evaluated using certified reference materials (CRMs) of river sediment, (BCR 320, NIST 2704, and 8704) and by comparison with values obtained by using the method recommended by the United States Environmental Protection Agency (EPA 3052). The agreement with the CRMs and with the official method were better than 95% for all analytes when 100 mg of sample, 5 mL of an extraction solution containing 4.75 mL of 3:1 HNO3:HCl (50%) + 0.25 mL of HF, and 20 min of heating (80 ºC) were used. Analytes were also determined by inductively coupled plasma optical emission spectrometry (ICP-OES) and no statistical difference was observed (t-test, 95% confidence level) compared to ICP-MS results. The analyte concentration in the PM samples ranged from 6.60 ± 0.41 to 17.9 ± 0.9 µg g-1 for As, from 0.839 ± 0.049 to 11.8 ± 0.6 µg g-1 for Cd, from 31.3 ± 2.1 to 59.6 ± 3.5 µg g-1 for Cr, and from 13.5 ± 0.5 to 123 ± 6 µg g-1 for Pb. Low limits of detection (LODs) of 0.90, 0.015, 0.640, and 0.085 µg g-1 were obtained for As, Cd, Cr, and Pb, respectively, which are important for the determination at low concentrations. Finally, the proposed method combined important advantages such as the use of a relatively low-cost sample preparation system (UAE method) with low reagent consumption, and a low volume of laboratory residues.

Authors

Publication Details

Journal
Brazilian Journal of Analytical Chemistry
Published
2025-06-09
DOI
https://doi.org/10.30744/brjac.2179-3425.ar-170-2024
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combining Ultrasound-Assisted Extraction and ICP-MS for As, Cd, Cr, and Pb Determination in Atmospheric Particulate Matter

Gabriel T. Druzian, Cristian R. Andriolli, Francisco Aécio Guedes Almeida, Rafael F. Santos et al.
Brazilian Journal of Analytical Chemistry
Analytical chemistry methods development
article

Combining Ultrasound-Assisted Extraction and ICP-MS for As, Cd, Cr, and Pb Determination in Atmospheric Particulate Matter

Gabriel T. Druzian, Cristian R. Andriolli, Francisco Aécio Guedes Almeida, Rafael F. Santos, Rochele S. Picoloto, Érico M.M. Flores
article en

Abstract

A simple, fast, and efficient ultrasound-assisted extraction (UAE) method for As, Cd, Cr, and Pb determination in atmospheric particulate matter (PM) by inductively coupled plasma mass spectrometry (ICP-MS) was developed. For the extraction procedure, the samples and the extraction solution were added directly into polypropylene vessels and placed in the ultrasound (US) bath. The following parameters were evaluated: i) sample mass: 50 to 500 mg, ii) extraction solutions: HNO3, HCl, and HF, and iii) extraction time in the US bath: 10 to 30 min (80 °C). Accuracy was evaluated using certified reference materials (CRMs) of river sediment, (BCR 320, NIST 2704, and 8704) and by comparison with values obtained by using the method recommended by the United States Environmental Protection Agency (EPA 3052). The agreement with the CRMs and with the official method were better than 95% for all analytes when 100 mg of sample, 5 mL of an extraction solution containing 4.75 mL of 3:1 HNO3:HCl (50%) + 0.25 mL of HF, and 20 min of heating (80 ºC) were used. Analytes were also determined by inductively coupled plasma optical emission spectrometry (ICP-OES) and no statistical difference was observed (t-test, 95% confidence level) compared to ICP-MS results. The analyte concentration in the PM samples ranged from 6.60 ± 0.41 to 17.9 ± 0.9 µg g-1 for As, from 0.839 ± 0.049 to 11.8 ± 0.6 µg g-1 for Cd, from 31.3 ± 2.1 to 59.6 ± 3.5 µg g-1 for Cr, and from 13.5 ± 0.5 to 123 ± 6 µg g-1 for Pb. Low limits of detection (LODs) of 0.90, 0.015, 0.640, and 0.085 µg g-1 were obtained for As, Cd, Cr, and Pb, respectively, which are important for the determination at low concentrations. Finally, the proposed method combined important advantages such as the use of a relatively low-cost sample preparation system (UAE method) with low reagent consumption, and a low volume of laboratory residues.

Brazilian Journal of Analytical ChemistryVol. 12(48)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul
Openalex Percentile: Top 86%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.