Experimental Investigation of Stall Mechanism and Warning Method in a Two-Stage Transonic Fan Under Inlet Distortion With Axial Slot Casing Treatment

Abstract A stall warning method has been employed to predict the level of disturbances in active control systems. Significant advancements have been made by identifying the pre-stall disturbances. Regardless of the propagation, disturbances almost initiate simultaneously at a specific circumferential location under uniform inflow. When the compressor suffers from inlet distortion, the disturbances might disappear in the undistorted region. The differences between the distorted and undistorted regions pose challenges for developing an accurate and robust warning method. Revealing the characteristics of pre-stall disturbances under the distorted inflow is a key to realize engineering applications. For this purpose, the stalling process and stall warning method are investigated in a two-stage transonic fan. The work on this project has concluded that the pre-stall disturbances initially arise in the region where the rotor exits the distorted region, diminish in the process of circumferential propagation, and ultimately disappear in the position where the rotor enters the distorted region. Due to the impact of circumferential secondary flow, the incidence is the largest and the fluctuation of the tip leakage flow is the strongest in the position where the rotor exits the distorted region. In the pursuit of an effective stall warning system under inlet distortion, a novel warning index associated with the characteristic frequency band is proposed. This index, coupled with a variable threshold, enables stall warning with only one transducer. The efficiency of this method is further validated in low-speed and transonic compressors.

Authors

Institutions

Publication Details

Journal
Journal of Turbomachinery
Published
2025-06-09
DOI
https://doi.org/10.1115/1.4068876
Citations
1
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
4.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation of Stall Mechanism and Warning Method in a Two-Stage Transonic Fan Under Inlet Distortion With Axial Slot Casing Treatment

Zhonggang Fan, Guofeng Ji, Dun Ba, Yang Liu et al.
1 citations
Journal of Turbomachinery
Turbomachinery Performance and Optimization
4.99
article

Experimental Investigation of Stall Mechanism and Warning Method in a Two-Stage Transonic Fan Under Inlet Distortion With Axial Slot Casing Treatment

Zhonggang Fan, Guofeng Ji, Dun Ba, Yang Liu, Min Zhang, Juan Du
article en
1 citations

Abstract

Abstract A stall warning method has been employed to predict the level of disturbances in active control systems. Significant advancements have been made by identifying the pre-stall disturbances. Regardless of the propagation, disturbances almost initiate simultaneously at a specific circumferential location under uniform inflow. When the compressor suffers from inlet distortion, the disturbances might disappear in the undistorted region. The differences between the distorted and undistorted regions pose challenges for developing an accurate and robust warning method. Revealing the characteristics of pre-stall disturbances under the distorted inflow is a key to realize engineering applications. For this purpose, the stalling process and stall warning method are investigated in a two-stage transonic fan. The work on this project has concluded that the pre-stall disturbances initially arise in the region where the rotor exits the distorted region, diminish in the process of circumferential propagation, and ultimately disappear in the position where the rotor enters the distorted region. Due to the impact of circumferential secondary flow, the incidence is the largest and the fluctuation of the tip leakage flow is the strongest in the position where the rotor exits the distorted region. In the pursuit of an effective stall warning system under inlet distortion, a novel warning index associated with the characteristic frequency band is proposed. This index, coupled with a variable threshold, enables stall warning with only one transducer. The efficiency of this method is further validated in low-speed and transonic compressors.

Journal of TurbomachineryVol. 147(12)
University of Canterbury (NZ), Institute of Engineering Thermophysics (UA), Aero Engine Corporation of China (China) (CN), Beijing Haidian Hospital (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 6%
Turbomachinery Performance and Optimization
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.