ReBP: Short-Term Blood Pressure Estimation by Reconstructing PPG Signals Based on mmWave Radar

Non-contact blood pressure (BP) monitoring offers significant potential for healthcare applications due to its convenience and comfort. However, existing methods often require prolonged signal acquisition to ensure accuracy, limiting real-time monitoring capabilities. This paper proposes Reconstructed Blood Pressure (ReBP), a millimeter-wave radar-based system for photoplethysmogram (PPG) signal reconstruction and BP estimation, achieving high accuracy with short-duration inputs. ReBP integrates four modules: data acquisition, signal processing, waveform reconstruction, and BP estimation. First, pulse signals from wrist vasculature are captured via mmWave radar. Then, an adaptive filtering algorithm enhances periodic characteristics by selecting segments with maximal autocorrelation. Subsequently, a Cycle-consistent Generative Adversarial Network (CycleGAN), augmented with a PPG-AWARE loss function, reconstructs PPG waveforms enriched with vascular dynamics. Finally, for BP estimation, a multi-feature fusion network extracts temporal, spectral, and global features via ResNet, Gated Recurrent Units (GRU), and SpectrogramLSTM, fused through a cross-modal attention mechanism. Implemented on a TI IWR6843 radar platform, ReBP was validated with 26 participants, achieving mean absolute errors (MAEs) of 3.891 mmHg (SBP) and 3.646 mmHg (DBP) for 35-second inputs, 4.003 mmHg (SBP) and 3.873 mmHg (DBP) for 15-second inputs, and 4.383 mmHg (SBP) and 4.115 mmHg (DBP) for 5-second inputs, outperforming conventional methods in short-sequence scenarios.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-06-09
DOI
https://doi.org/10.1109/jsen.2025.3576133
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ReBP: Short-Term Blood Pressure Estimation by Reconstructing PPG Signals Based on mmWave Radar

Biyun Sheng, Chong Han, Ying Wang, Weiqing Bai et al.
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
article

ReBP: Short-Term Blood Pressure Estimation by Reconstructing PPG Signals Based on mmWave Radar

Biyun Sheng, Chong Han, Ying Wang, Weiqing Bai, Jialiang Ma
article en

Abstract

Non-contact blood pressure (BP) monitoring offers significant potential for healthcare applications due to its convenience and comfort. However, existing methods often require prolonged signal acquisition to ensure accuracy, limiting real-time monitoring capabilities. This paper proposes Reconstructed Blood Pressure (ReBP), a millimeter-wave radar-based system for photoplethysmogram (PPG) signal reconstruction and BP estimation, achieving high accuracy with short-duration inputs. ReBP integrates four modules: data acquisition, signal processing, waveform reconstruction, and BP estimation. First, pulse signals from wrist vasculature are captured via mmWave radar. Then, an adaptive filtering algorithm enhances periodic characteristics by selecting segments with maximal autocorrelation. Subsequently, a Cycle-consistent Generative Adversarial Network (CycleGAN), augmented with a PPG-AWARE loss function, reconstructs PPG waveforms enriched with vascular dynamics. Finally, for BP estimation, a multi-feature fusion network extracts temporal, spectral, and global features via ResNet, Gated Recurrent Units (GRU), and SpectrogramLSTM, fused through a cross-modal attention mechanism. Implemented on a TI IWR6843 radar platform, ReBP was validated with 26 participants, achieving mean absolute errors (MAEs) of 3.891 mmHg (SBP) and 3.646 mmHg (DBP) for 35-second inputs, 4.003 mmHg (SBP) and 3.873 mmHg (DBP) for 15-second inputs, and 4.383 mmHg (SBP) and 4.115 mmHg (DBP) for 5-second inputs, outperforming conventional methods in short-sequence scenarios.

IEEE Sensors JournalVol. 25(14)
Nanjing University of Posts and Telecommunications (CN)
National Natural Science Foundation of China, Natural Science Foundation of Heilongjiang Province
Openalex Percentile: Top 88%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ReBP: Short-Term Blood Pressure Estimation by Reconstructing PPG Signals Based on mmWave Radar — Biyun Sheng, Chong Han, et al. · IEEE Sensors Journal (2025) | TGRS Research Map | TGRS