optiGAN: a deep learning-based alternative to optical photon tracking in Python-based GATE (10+)

<i>Objective.</i>To accelerate optical photon transport simulations in the GATE medical physics framework using a generative adversarial network (GAN), while ensuring high modeling accuracy. Traditionally, detailed optical Monte Carlo methods have been the gold standard for modeling photon interactions in detectors, but their high computational cost remains a challenge. This study explores the integration of optiGAN, a GAN model into GATE 10, the new Python-based version of the GATE medical physics simulation framework released in November 2024.<i>Approach.</i>The goal of optiGAN is to accelerate optical photon transport simulations while maintaining modeling accuracy. The optiGAN model, based on a GAN architecture, was integrated into GATE 10 as a computationally efficient alternative to traditional optical Monte Carlo simulations. To ensure consistency, optical photon transport modules were implemented in GATE 10 and validated against GATE v9.3 under identical simulation conditions. Subsequently, simulations using full Monte Carlo tracking in GATE 10 were compared to those using GATE 10-optiGAN.<i>Main results.</i>Validation studies confirmed that GATE 10 produces results consistent with GATE v9.3. Simulations using GATE 10-optiGAN showed over 92% similarity to Monte Carlo-based GATE 10 results, based on the Jensen-Shannon distance across multiple photon transport parameters. optiGAN successfully captured multimodal distributions of photon position, direction, and energy at the photodetector face. Simulation time analysis revealed a reduction of approximately 50% in execution time with GATE 10-optiGAN compared to full Monte Carlo simulations.<i>Significance.</i>The study confirms both the fidelity of optical photon transport modeling in GATE 10 and the effective integration of deep learning-based acceleration through optiGAN. This advancement enables large-scale, high-fidelity optical simulations with significantly reduced computational cost, supporting broader applications in medical imaging and detector design.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-06-09
DOI
https://doi.org/10.1088/1361-6560/ade2b5
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

optiGAN: a deep learning-based alternative to optical photon tracking in Python-based GATE (10+)

Nils Krah, Emilie Roncali, Carlotta Trigila, David Sarrut et al.
1 citations
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
1.36
article

optiGAN: a deep learning-based alternative to optical photon tracking in Python-based GATE (10+)

Nils Krah, Emilie Roncali, Carlotta Trigila, David Sarrut, Guneet Mummaneni
article en
1 citations

Abstract

<i>Objective.</i>To accelerate optical photon transport simulations in the GATE medical physics framework using a generative adversarial network (GAN), while ensuring high modeling accuracy. Traditionally, detailed optical Monte Carlo methods have been the gold standard for modeling photon interactions in detectors, but their high computational cost remains a challenge. This study explores the integration of optiGAN, a GAN model into GATE 10, the new Python-based version of the GATE medical physics simulation framework released in November 2024.<i>Approach.</i>The goal of optiGAN is to accelerate optical photon transport simulations while maintaining modeling accuracy. The optiGAN model, based on a GAN architecture, was integrated into GATE 10 as a computationally efficient alternative to traditional optical Monte Carlo simulations. To ensure consistency, optical photon transport modules were implemented in GATE 10 and validated against GATE v9.3 under identical simulation conditions. Subsequently, simulations using full Monte Carlo tracking in GATE 10 were compared to those using GATE 10-optiGAN.<i>Main results.</i>Validation studies confirmed that GATE 10 produces results consistent with GATE v9.3. Simulations using GATE 10-optiGAN showed over 92% similarity to Monte Carlo-based GATE 10 results, based on the Jensen-Shannon distance across multiple photon transport parameters. optiGAN successfully captured multimodal distributions of photon position, direction, and energy at the photodetector face. Simulation time analysis revealed a reduction of approximately 50% in execution time with GATE 10-optiGAN compared to full Monte Carlo simulations.<i>Significance.</i>The study confirms both the fidelity of optical photon transport modeling in GATE 10 and the effective integration of deep learning-based acceleration through optiGAN. This advancement enables large-scale, high-fidelity optical simulations with significantly reduced computational cost, supporting broader applications in medical imaging and detector design.

Physics in Medicine and BiologyVol. 70(13)
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Inserm (FR), Proton Therapy Centre (CZ), Centre Léon Bérard (FR), Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (FR), University of California, Davis (US)
National Institute of Biomedical Imaging and Bioengineering
Affordable and clean energy
Openalex Percentile: Top 19%
Medical Imaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.