Simulation and one-ring prototyping of 1 mm-rod-resolution hemispherical brain PET with TOF-DOI detectors

<i>Objective.</i>Brain positron emission tomography (PET) imaging plays crucial roles in research and diagnosis of various brain diseases. To achieve high spatial resolution and high sensitivity, we proposed a hemispherical geometry which offers higher sensitivity with fewer detectors than a conventional cylindrical geometry. Our developed hemispherical brain PET system, Vrain, has indeed achieved a rod resolution of 2.2 mm with a 229 ps time-of-flight (TOF) resolution. To further improve the spatial resolution, we will use TOF and depth-of-interaction (DOI) detectors with our original crosshair light-sharing (CLS) configuration. This study aimed at estimating the performance of the hemispherical brain PET with TOF-DOI detectors and at developing a one-ring PET prototype with 1.6 mm scintillator pitch CLS-based TOF-DOI detectors.<i>Approach.</i>The sensitivity, rod resolution, and image quality of the TOF-DOI hemispherical brain PET (TDHBP-sim) and Vrain (Vrain-sim) were estimated using Geant4 simulation. A one-ring prototype with a 30 cm diameter was developed using the CLS-based TOF-DOI detectors. The energy resolution, TOF timing resolution, rod resolution, and the Hoffman brain phantom image quality of the prototype were evaluated.<i>Main results.</i>In the simulation study, TDHBP-sim achieved 1.4 times better sensitivity than Vrain-sim. TDHBP-sim visualized 1.0 mm rods and gyri and sulci structures in the brain phantom. In the one-ring experiment, the energy resolution was 11.6% at 511 keV, the TOF timing resolution was 294.6 ps, and 1.0 mm rods were resolved at the central 10 cm-diameter field-of-view. The 0.8 mm-thick radioactivity distribution could be identified in the Hoffman phantom.<i>Significance.</i>The study findings suggested that a hemispherical brain PET with 1.6 mm scintillator pitch TOF-DOI detectors should offer excellent performance including 1 mm rod resolution.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-06-09
DOI
https://doi.org/10.1088/1361-6560/ade2b4
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation and one-ring prototyping of 1 mm-rod-resolution hemispherical brain PET with TOF-DOI detectors

Hideaki Tashima, Taiga Yamaya, Go Akamatsu, Eiji Yoshida et al.
2 citations
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
2.72
article

Simulation and one-ring prototyping of 1 mm-rod-resolution hemispherical brain PET with TOF-DOI detectors

Hideaki Tashima, Taiga Yamaya, Go Akamatsu, Eiji Yoshida, M. Takahashi, Yuma Iwao, K Narita
article en
2 citations

Abstract

<i>Objective.</i>Brain positron emission tomography (PET) imaging plays crucial roles in research and diagnosis of various brain diseases. To achieve high spatial resolution and high sensitivity, we proposed a hemispherical geometry which offers higher sensitivity with fewer detectors than a conventional cylindrical geometry. Our developed hemispherical brain PET system, Vrain, has indeed achieved a rod resolution of 2.2 mm with a 229 ps time-of-flight (TOF) resolution. To further improve the spatial resolution, we will use TOF and depth-of-interaction (DOI) detectors with our original crosshair light-sharing (CLS) configuration. This study aimed at estimating the performance of the hemispherical brain PET with TOF-DOI detectors and at developing a one-ring PET prototype with 1.6 mm scintillator pitch CLS-based TOF-DOI detectors.<i>Approach.</i>The sensitivity, rod resolution, and image quality of the TOF-DOI hemispherical brain PET (TDHBP-sim) and Vrain (Vrain-sim) were estimated using Geant4 simulation. A one-ring prototype with a 30 cm diameter was developed using the CLS-based TOF-DOI detectors. The energy resolution, TOF timing resolution, rod resolution, and the Hoffman brain phantom image quality of the prototype were evaluated.<i>Main results.</i>In the simulation study, TDHBP-sim achieved 1.4 times better sensitivity than Vrain-sim. TDHBP-sim visualized 1.0 mm rods and gyri and sulci structures in the brain phantom. In the one-ring experiment, the energy resolution was 11.6% at 511 keV, the TOF timing resolution was 294.6 ps, and 1.0 mm rods were resolved at the central 10 cm-diameter field-of-view. The 0.8 mm-thick radioactivity distribution could be identified in the Hoffman phantom.<i>Significance.</i>The study findings suggested that a hemispherical brain PET with 1.6 mm scintillator pitch TOF-DOI detectors should offer excellent performance including 1 mm rod resolution.

Physics in Medicine and BiologyVol. 70(12)
Chiba University (JP), National Institutes for Quantum Science and Technology (JP)
Japan Agency for Medical Research and Development
Affordable and clean energy
Openalex Percentile: Top 10%
Medical Imaging Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.