Comparative analysis of convolutional neural networks and vision transformers in identifying benign and malignant breast lesions

Various deep learning models have been developed and employed for medical image classification. This study conducted comprehensive experiments on 12 models, aiming to establish reliable benchmarks for research on breast dynamic contrast-enhanced magnetic resonance imaging image classification. Twelve deep learning models were systematically compared by analyzing variations in 4 key hyperparameters: optimizer (Op), learning rate, batch size (BS), and data augmentation. The evaluation criteria encompassed a comprehensive set of metrics including accuracy (Ac), loss value, precision, recall rate, F1-score, and area under the receiver operating characteristic curve. Furthermore, the training times and model parameter counts were assessed for holistic performance comparison. Adjustments in the BS within Adam Op had a minimal impact on Ac in the convolutional neural network models. However, altering the Op and learning rate while maintaining the same BS significantly affected the Ac. The ResNet152 network model exhibited the lowest Ac. Both the recall rate and area under the receiver operating characteristic curve for the ResNet152 and Vision transformer-base (ViT) models were inferior compared to the others. Data augmentation unexpectedly reduced the Ac of ResNet50, ResNet152, VGG16, VGG19, and ViT models. The VGG16 model boasted the shortest training duration, whereas the ViT model, before data augmentation, had the longest training time and smallest model weight. The ResNet152 and ViT models were not well suited for image classification tasks involving small breast dynamic contrast-enhanced magnetic resonance imaging datasets. Although data augmentation is typically beneficial, its application should be approached cautiously. These findings provide important insights to inform and refine future research in this domain.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-06-06
DOI
https://doi.org/10.1097/md.0000000000042683
Citations
3
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
4.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative analysis of convolutional neural networks and vision transformers in identifying benign and malignant breast lesions

Shu Fang, Mingzhu Meng, Long Wang, Xiaoxia Chen et al.
3 citations
Medicine
Radiomics and Machine Learning in Medical Imaging
4.08
article

Comparative analysis of convolutional neural networks and vision transformers in identifying benign and malignant breast lesions

Shu Fang, Mingzhu Meng, Long Wang, Xiaoxia Chen, Changjie Pan
article en
3 citations

Abstract

Various deep learning models have been developed and employed for medical image classification. This study conducted comprehensive experiments on 12 models, aiming to establish reliable benchmarks for research on breast dynamic contrast-enhanced magnetic resonance imaging image classification. Twelve deep learning models were systematically compared by analyzing variations in 4 key hyperparameters: optimizer (Op), learning rate, batch size (BS), and data augmentation. The evaluation criteria encompassed a comprehensive set of metrics including accuracy (Ac), loss value, precision, recall rate, F1-score, and area under the receiver operating characteristic curve. Furthermore, the training times and model parameter counts were assessed for holistic performance comparison. Adjustments in the BS within Adam Op had a minimal impact on Ac in the convolutional neural network models. However, altering the Op and learning rate while maintaining the same BS significantly affected the Ac. The ResNet152 network model exhibited the lowest Ac. Both the recall rate and area under the receiver operating characteristic curve for the ResNet152 and Vision transformer-base (ViT) models were inferior compared to the others. Data augmentation unexpectedly reduced the Ac of ResNet50, ResNet152, VGG16, VGG19, and ViT models. The VGG16 model boasted the shortest training duration, whereas the ViT model, before data augmentation, had the longest training time and smallest model weight. The ResNet152 and ViT models were not well suited for image classification tasks involving small breast dynamic contrast-enhanced magnetic resonance imaging datasets. Although data augmentation is typically beneficial, its application should be approached cautiously. These findings provide important insights to inform and refine future research in this domain.

MedicineVol. 104(23)
Soochow University (CN), Nanjing Traditional Chinese Medicine Hospital (CN), Hangzhou Hospital of Traditional Chinese Medicine (CN), First Affiliated Hospital of Soochow University (CN)
Openalex Percentile: Top 6%
Radiomics and Machine Learning in Medical Imaging
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.