Study on the Correlation between i <sub>pa</sub> and i <sub>pc</sub> of Electrode in Vanadium Flow Batteries by In‐Situ Weak Measurement Imaging

Traditional characterization techniques for vanadium flow batteries (VFBs) electrodes demonstrate significant limitations in resolving spatially heterogeneous reaction characteristics on electrode surfaces and efficiently characterizing large-scale working electrodes. Consequently, mapping electrode activity distributions and establishing efficient screening strategies for high-performance electrodes are critical for advancing VFBs research. Building on prior studies, this work employs weak measurement imaging (WMi) methodology to spatially characterize reaction activity distributions on VFBs positive electrode surfaces and quantitatively analyze electrode reaction parameters (i<sub>pa</sub> and i<sub>pc</sub>). By statistically comparing extensive electrochemical data from working electrodes (randomly sampled from large graphite felt substrates and tested via electrochemical workstation, EW) with WMi-derived data from individual electrodes, a pronounced linear correlation between oxidation and reduction peak current densities (i<sub>pa</sub> and i<sub>pc</sub>) in VFBs working electrodes is identified. Systematic investigations of graphite felt (GF) and thermally activated graphite felt (TGF) electrodes under varied operational conditions confirmed this statistical relationship between i<sub>pa</sub> and i<sub>pc</sub> while validating the reliability of the WMi sensing system. This findings demonstrate that the WMi sensing system serves as a robust and versatile analytical tool for quantitatively characterizing electrode performance parameters. This approach facilitates efficient screening of high-performance VFBs working electrodes, thereby accelerating the development of flow battery technologies.

Authors

Institutions

Publication Details

Journal
Small
Published
2025-06-09
DOI
https://doi.org/10.1002/smll.202505051
Primary Topic
Advanced battery technologies research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Correlation between i pa and i pc of Electrode in Vanadium Flow Batteries by In‐Situ Weak Measurement Imaging

Xiangheng Niu, Hao Yang Lin, Qi Yang, Yang Xu et al.
Small
Advanced battery technologies research
article

Study on the Correlation between i pa and i pc of Electrode in Vanadium Flow Batteries by In‐Situ Weak Measurement Imaging

Xiangheng Niu, Hao Yang Lin, Qi Yang, Yang Xu, Le Liu, Liang Tan, Dongzhi Li, Jingyu Xi, Zixin Wu
article en

Abstract

Traditional characterization techniques for vanadium flow batteries (VFBs) electrodes demonstrate significant limitations in resolving spatially heterogeneous reaction characteristics on electrode surfaces and efficiently characterizing large-scale working electrodes. Consequently, mapping electrode activity distributions and establishing efficient screening strategies for high-performance electrodes are critical for advancing VFBs research. Building on prior studies, this work employs weak measurement imaging (WMi) methodology to spatially characterize reaction activity distributions on VFBs positive electrode surfaces and quantitatively analyze electrode reaction parameters (i<sub>pa</sub> and i<sub>pc</sub>). By statistically comparing extensive electrochemical data from working electrodes (randomly sampled from large graphite felt substrates and tested via electrochemical workstation, EW) with WMi-derived data from individual electrodes, a pronounced linear correlation between oxidation and reduction peak current densities (i<sub>pa</sub> and i<sub>pc</sub>) in VFBs working electrodes is identified. Systematic investigations of graphite felt (GF) and thermally activated graphite felt (TGF) electrodes under varied operational conditions confirmed this statistical relationship between i<sub>pa</sub> and i<sub>pc</sub> while validating the reliability of the WMi sensing system. This findings demonstrate that the WMi sensing system serves as a robust and versatile analytical tool for quantitatively characterizing electrode performance parameters. This approach facilitates efficient screening of high-performance VFBs working electrodes, thereby accelerating the development of flow battery technologies.

SmallVol. 21(31)
Guangdong University of Technology (CN), Tsinghua–Berkeley Shenzhen Institute (CN), Shenzhen Children's Hospital (CN), Tsinghua University (CN)
Innovative Research Group Project of the National Natural Science Foundation of China, National Natural Science Foundation of China, Shenzhen Science and Technology Innovation Program
Openalex Percentile: Top 89%
Advanced battery technologies research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.