Catalytic Hairpin Assembly‐Propelled Weak‐Inputs‐Strong‐Outputs (CP‐WISO) DNA Logic Nanodevices with Orthogonal Design and Contrary Logic Responses

Developing innovative multi-channel DNA logic systems with strong responses for weak inputs is of paramount significance for versatile molecular computing, information processing, smart biosensing, and early medical diagnostics. However, most previous works usually necessitate abundant inputs equivalent to signal probes or computing elements, and present only single-channel outputs, causing DNAs' over-consumption, limited computing functions, flexibility, and maneuverability. Herein, assisted with a catalytic-hairpin-assembly (CHA) amplifier and rational orthogonal design, the first universal weak-inputs-strong-outputs DNA system (named CP-WISO) with contrary logic responses is reported, which exhibited noticeable advantages over previous works. 1) Excellent FRET effect of dual-signal DNA probes (Cy3/Cy5) brought enriched contrary logic output channels; 2) One-step CHA amplification avoided DNAs' over-consumption, high cost, and complexity; 3) A library of CP-WISO DNA logic nanodevices with the manipulated orthogonal design is realized, accompanied with enhanced flexibility, maneuverability, and computing proficiency; 4) Even and odd parity generators/checkers (pG/pC) are concurrently operated based on the "XOR∧XNOR"-type CP-WISO nanodevice, ensuring the recognition of erroneous bits and secure molecular data transmission; 5) Additionally, taking miRNA-499, miRNA-21 and miRNA-122 as alternative model targets, the "YES∧NOT" and "AND∧NAND" CP-WISO nanodevices achieved intelligent identification and ratiometric fluorescent detection of miRNAs in human serums, promoting the early diagnostics of acute myocardial infarction and liver cancer.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2025-06-09
DOI
https://doi.org/10.1002/advs.202501430
Citations
4
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
3.22

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Catalytic Hairpin Assembly‐Propelled Weak‐Inputs‐Strong‐Outputs (CP‐WISO) DNA Logic Nanodevices with Orthogonal Design and Contrary Logic Responses

Xingchen Yan, Baojian Huang, Xujuan Lv, Jiawen Han et al.
4 citations
Advanced Science
Advanced biosensing and bioanalysis techniques
3.22
article

Catalytic Hairpin Assembly‐Propelled Weak‐Inputs‐Strong‐Outputs (CP‐WISO) DNA Logic Nanodevices with Orthogonal Design and Contrary Logic Responses

Xingchen Yan, Baojian Huang, Xujuan Lv, Jiawen Han, Daoqing Fan, Juan Wang, Shuai Qin, Zhihua Lv, Shaojun Dong
article en
4 citations

Abstract

Developing innovative multi-channel DNA logic systems with strong responses for weak inputs is of paramount significance for versatile molecular computing, information processing, smart biosensing, and early medical diagnostics. However, most previous works usually necessitate abundant inputs equivalent to signal probes or computing elements, and present only single-channel outputs, causing DNAs' over-consumption, limited computing functions, flexibility, and maneuverability. Herein, assisted with a catalytic-hairpin-assembly (CHA) amplifier and rational orthogonal design, the first universal weak-inputs-strong-outputs DNA system (named CP-WISO) with contrary logic responses is reported, which exhibited noticeable advantages over previous works. 1) Excellent FRET effect of dual-signal DNA probes (Cy3/Cy5) brought enriched contrary logic output channels; 2) One-step CHA amplification avoided DNAs' over-consumption, high cost, and complexity; 3) A library of CP-WISO DNA logic nanodevices with the manipulated orthogonal design is realized, accompanied with enhanced flexibility, maneuverability, and computing proficiency; 4) Even and odd parity generators/checkers (pG/pC) are concurrently operated based on the "XOR∧XNOR"-type CP-WISO nanodevice, ensuring the recognition of erroneous bits and secure molecular data transmission; 5) Additionally, taking miRNA-499, miRNA-21 and miRNA-122 as alternative model targets, the "YES∧NOT" and "AND∧NAND" CP-WISO nanodevices achieved intelligent identification and ratiometric fluorescent detection of miRNAs in human serums, promoting the early diagnostics of acute myocardial infarction and liver cancer.

Advanced ScienceVol. 12(33)
Qingdao University (CN), Qingdao University of Science and Technology (CN), Chinese Academy of Sciences (CN), Changchun Institute of Applied Chemistry (CN), Qingdao Academy of Intelligent Industries (CN), Qingdao National Laboratory for Marine Science and Technology (CN), Ocean University of China (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Fundamental Research Funds for the Central Universities
Industry, innovation and infrastructure
Openalex Percentile: Top 8%
Advanced biosensing and bioanalysis techniques
3.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.