Analysis of high-frequency oscillation mechanism of inverter with motor load based on series resonance

• Reveals high-frequency oscillation mechanisms of system through series resonance. • Aggregated impedance stability criteria quantitatively analyze stability margins. • Proportional coefficient of voltage loop significantly affects system stability. • Higher-power motors help improve system stability. Inverter-driven asynchronous motor loads represent typical operational scenarios in shipboard integrated power systems. The inverter’s output impedance characteristics are influenced by complex control dynamics, and the interaction between source and load impedances presents a risk of high-frequency resonance. To address this, this paper first uses the harmonic linearization method to establish sequence impedance models of the inverter and asynchronous motor. It analyses the high-frequency impedance characteristics of the source and load, developing an equivalent high-frequency RLC circuit model. The oscillation mechanism is revealed from the perspective of system series resonance. Specifically, when the positive resistance of the load subsystem at the series resonance frequency cannot counteract the negative resistance effect of the source subsystem, the system’s series resonance high-frequency oscillation mode exhibits negative damping characteristics, leading to instability. Secondly, to quantitatively evaluate system stability, the aggregated impedance stability criterion is derived from the Nyquist stability criterion. This criterion is used to analyse the influence of inverter control parameters and motor power on stability. Results indicate that as the proportional coefficient of voltage loop increases, the voltage feedforward coefficient increases, and the current feedforward coefficient decreases, the system’s high-frequency oscillation stability margin decreases. However, motor with higher power improve stability.

Authors

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2025-06-09
DOI
https://doi.org/10.1016/j.ijepes.2025.110799
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of high-frequency oscillation mechanism of inverter with motor load based on series resonance

Yunfeng Lin, Yanhong Ma, Qi Hu, Fu Lijun et al.
International Journal of Electrical Power & Energy Systems
Microgrid Control and Optimization
article

Analysis of high-frequency oscillation mechanism of inverter with motor load based on series resonance

Yunfeng Lin, Yanhong Ma, Qi Hu, Fu Lijun, Liu Chenruiyang
article en

Abstract

• Reveals high-frequency oscillation mechanisms of system through series resonance. • Aggregated impedance stability criteria quantitatively analyze stability margins. • Proportional coefficient of voltage loop significantly affects system stability. • Higher-power motors help improve system stability. Inverter-driven asynchronous motor loads represent typical operational scenarios in shipboard integrated power systems. The inverter’s output impedance characteristics are influenced by complex control dynamics, and the interaction between source and load impedances presents a risk of high-frequency resonance. To address this, this paper first uses the harmonic linearization method to establish sequence impedance models of the inverter and asynchronous motor. It analyses the high-frequency impedance characteristics of the source and load, developing an equivalent high-frequency RLC circuit model. The oscillation mechanism is revealed from the perspective of system series resonance. Specifically, when the positive resistance of the load subsystem at the series resonance frequency cannot counteract the negative resistance effect of the source subsystem, the system’s series resonance high-frequency oscillation mode exhibits negative damping characteristics, leading to instability. Secondly, to quantitatively evaluate system stability, the aggregated impedance stability criterion is derived from the Nyquist stability criterion. This criterion is used to analyse the influence of inverter control parameters and motor power on stability. Results indicate that as the proportional coefficient of voltage loop increases, the voltage feedforward coefficient increases, and the current feedforward coefficient decreases, the system’s high-frequency oscillation stability margin decreases. However, motor with higher power improve stability.

International Journal of Electrical Power & Energy SystemsVol. 169
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 86%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of high-frequency oscillation mechanism of inverter with motor load based on series resonance — Yunfeng Lin, Yanhong Ma, et al. · International Journal of Electrical Power & Energy Systems (2025) | TGRS Research Map | TGRS