Dynamic calibration of flow meters using reference flow rate profiles generated by injectors

• Development of a new method for dynamic calibration of flow meters. • Realization of a test bench for flow meter dynamic calibration. • Generation of flow rate profiles by using injectors. • Realization of reference flow rate profiles. • Analysis of the generated profile and evaluation of the uncertainty. A new method to calibrate flow meters under dynamic conditions has been developed, based on the generation of variable reference flow rates using an automotive injection system. The method was tested with different flow profiles, including both idealized flow time-histories (sinusoidal and sawtooth waves) and actual fuel flow rate profiles recorded during WLTP (Worldwide harmonized Light vehicles Test Procedure) automotive type-approval tests. To demonstrate the effectiveness of the method, some results obtained with a Coriolis flow meter are presented. Compared with other methods such as those based on valves or volumetric pistons, the reference flow rate profiles obtained by the proposed approach feature dynamic characteristics (mainly flow oscillation time and gradients) that can be easily tailored to specific applications. The method has a high potential in evaluating the dynamic response of flow meters, which can be very different from that obtained with constant flow calibration.

Authors

Institutions

Publication Details

Journal
Measurement
Published
2025-06-08
DOI
https://doi.org/10.1016/j.measurement.2025.118129
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic calibration of flow meters using reference flow rate profiles generated by injectors

Andrea Malengo, Lucio Postrioti, Manuel Martino, Davide Torchio et al.
Measurement
Flow Measurement and Analysis
article

Dynamic calibration of flow meters using reference flow rate profiles generated by injectors

Andrea Malengo, Lucio Postrioti, Manuel Martino, Davide Torchio, R. Romeo
article en

Abstract

• Development of a new method for dynamic calibration of flow meters. • Realization of a test bench for flow meter dynamic calibration. • Generation of flow rate profiles by using injectors. • Realization of reference flow rate profiles. • Analysis of the generated profile and evaluation of the uncertainty. A new method to calibrate flow meters under dynamic conditions has been developed, based on the generation of variable reference flow rates using an automotive injection system. The method was tested with different flow profiles, including both idealized flow time-histories (sinusoidal and sawtooth waves) and actual fuel flow rate profiles recorded during WLTP (Worldwide harmonized Light vehicles Test Procedure) automotive type-approval tests. To demonstrate the effectiveness of the method, some results obtained with a Coriolis flow meter are presented. Compared with other methods such as those based on valves or volumetric pistons, the reference flow rate profiles obtained by the proposed approach feature dynamic characteristics (mainly flow oscillation time and gradients) that can be easily tailored to specific applications. The method has a high potential in evaluating the dynamic response of flow meters, which can be very different from that obtained with constant flow calibration.

MeasurementVol. 256
University of Perugia (IT), Istituto Nazionale di Ricerca Metrologica (IT)
Horizon 2020 Framework Programme, European Metrology Programme for Innovation and Research
Affordable and clean energy
Openalex Percentile: Top 86%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dynamic calibration of flow meters using reference flow rate profiles generated by injectors — Andrea Malengo, Lucio Postrioti, et al. · Measurement (2025) | TGRS Research Map | TGRS