Design and analysis of wedge type porous structured implants fabricated from additive manufacturing (AM) technique for optimum stress shielding effect

Recent advances in additive manufacturing have shown that porous cellular architectures can help reduce stress shielding in implants. This study used finite element analysis (FEA) to design wedge-shaped implants with lower elastic modulus, incorporating triply periodic minimal surface structures-specifically Gyroid and Schwarz-P types. Designs considered selective laser melting constraints, and produced using Ti6Al4V with five porosity levels (55-75%). Compression simulations revealed that increasing porosity decreased both Young's modulus and yield strength. The 75% porous Gyroid structure had the lowest Young's modulus (12.81 GPa), closest to that of natural bone. These results suggest FEA can effectively guide the design of bone-mimicking implants.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-06-08
DOI
https://doi.org/10.1080/10255842.2025.2514796
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and analysis of wedge type porous structured implants fabricated from additive manufacturing (AM) technique for optimum stress shielding effect

Tolga Meral, Ramazan Özmen, Mustafa Günay
1 citations
Computer Methods in Biomechanics & Biomedical Engineering
Bone Tissue Engineering Materials
0.67
article

Design and analysis of wedge type porous structured implants fabricated from additive manufacturing (AM) technique for optimum stress shielding effect

Tolga Meral, Ramazan Özmen, Mustafa Günay
article en
1 citations

Abstract

Recent advances in additive manufacturing have shown that porous cellular architectures can help reduce stress shielding in implants. This study used finite element analysis (FEA) to design wedge-shaped implants with lower elastic modulus, incorporating triply periodic minimal surface structures-specifically Gyroid and Schwarz-P types. Designs considered selective laser melting constraints, and produced using Ti6Al4V with five porosity levels (55-75%). Compression simulations revealed that increasing porosity decreased both Young's modulus and yield strength. The 75% porous Gyroid structure had the lowest Young's modulus (12.81 GPa), closest to that of natural bone. These results suggest FEA can effectively guide the design of bone-mimicking implants.

Computer Methods in Biomechanics & Biomedical Engineering
Bursa Uludağ Üni̇versi̇tesi̇ (TR), Karabük University (TR)
Openalex Percentile: Top 31%
Bone Tissue Engineering Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.