Effects of Plate‐Bone Contact on Bridge Plate Fracture Fixation Biomechanics: Computational, Experimental, and Analytical Modeling

Bridge plating is commonly used for internal fixation of comminuted fractures. The inner working length between screws has been established as a key parameter controlling postoperative biomechanical stability. However, plate-bone contact may affect these biomechanics in complex ways, and the offset between the plate and bone is variable across surgeries. The objective of this study was to examine the effects of construct and loading parameters on interfragmentary motion and maximum plate stress of bridge plating constructs. Finite element models were developed with variations in inner working length, plate-bone offset, fracture gap size, and loading type and magnitudes. Experiments with synthetic bones were conducted in parallel to support model credibility. Analytical models were also developed based on beam bending and torsion of the plate, assuming rigidity outside the inner working length. Finite element and experimental results of axial and torsional loading scenarios without plate-bone contact confirmed linear relationships between inner working length and interfragmentary motion. Analytical predictions of interfragmentary motion showed very good agreement with the finite element simulations in these scenarios. Conversely, in cases with plate-bone contact, a shorter effective working length was formed, and results were dependent on additional variables such as fracture gap. The study shows how the mechanics of bridge plating can be understood and predicted based on beam theory up to the point of plate-bone contact, and how interfragmentary motions and maximum plate stresses are influenced by the interaction of surgical variables in the presence of plate-bone contact.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2025-06-08
DOI
https://doi.org/10.1002/jor.26114
Citations
1
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Plate‐Bone Contact on Bridge Plate Fracture Fixation Biomechanics: Computational, Experimental, and Analytical Modeling

Gregory S. Lewis, J. Spence Reid, Zachary Koroneos, Hwabok Wee
1 citations
Journal of Orthopaedic Research®
Bone fractures and treatments
1.35
article

Effects of Plate‐Bone Contact on Bridge Plate Fracture Fixation Biomechanics: Computational, Experimental, and Analytical Modeling

Gregory S. Lewis, J. Spence Reid, Zachary Koroneos, Hwabok Wee
article en
1 citations

Abstract

Bridge plating is commonly used for internal fixation of comminuted fractures. The inner working length between screws has been established as a key parameter controlling postoperative biomechanical stability. However, plate-bone contact may affect these biomechanics in complex ways, and the offset between the plate and bone is variable across surgeries. The objective of this study was to examine the effects of construct and loading parameters on interfragmentary motion and maximum plate stress of bridge plating constructs. Finite element models were developed with variations in inner working length, plate-bone offset, fracture gap size, and loading type and magnitudes. Experiments with synthetic bones were conducted in parallel to support model credibility. Analytical models were also developed based on beam bending and torsion of the plate, assuming rigidity outside the inner working length. Finite element and experimental results of axial and torsional loading scenarios without plate-bone contact confirmed linear relationships between inner working length and interfragmentary motion. Analytical predictions of interfragmentary motion showed very good agreement with the finite element simulations in these scenarios. Conversely, in cases with plate-bone contact, a shorter effective working length was formed, and results were dependent on additional variables such as fracture gap. The study shows how the mechanics of bridge plating can be understood and predicted based on beam theory up to the point of plate-bone contact, and how interfragmentary motions and maximum plate stresses are influenced by the interaction of surgical variables in the presence of plate-bone contact.

Journal of Orthopaedic Research®Vol. 43(9)
Pennsylvania State University (US), Penn State Milton S. Hershey Medical Center (US)
National Institutes of Health
Openalex Percentile: Top 19%
Bone fractures and treatments
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.