Towards real-time process monitoring and control of physical properties of tablets using terahertz spectroscopy

• The developed interface enables automated THz-TDS* measurements. • The developed algorithm sorts THz-TDS* data and detects outliers automatically. • 1 st and 2 nd step enable monitoring of physical attributes of pharmaceutical tablets. • Considerations for controlling pharmaceutical tableting using THz-TDS* The modernisation of pharmaceutical manufacturing requires the implementation of process analysers for real-time assessment of both the process and product quality, as part of a process analytical technology (PAT) strategy. To meet the high standards for data integrity, it is essential that process analysers are integrated with a suitable sampling interface and workflow to ensure a reproducible sample presentation and robust data processing strategy. Terahertz time-domain spectroscopy (THz-TDS) with a reflection setup has recently been introduced as a potential process analyser for a fast assessment of tablet thickness, porosity, and mass, simultaneously. This study explores the potential of automated THz-TDS measurements, including the testing of a novel sampling interface prototype coupled with an algorithm for data treatment to select and group tablet measurements from background noise. Sampling interface and algorithm reliably presented, identified, and subsequently analysed THz-TDS signals of tablets. Comparable model errors were observed between the in-line interface and non-automated off-line manual measurements, with root mean square errors (RMSEs) of ≤ 0.012 mm, ≤ 1.23 %, ≤ 1.3 mg for tablet thickness, porosity, and mass, respectively. Additionally, the potential for off-line calibration, ongoing model maintenance of the analytical procedure, and integration within a PAT framework for monitoring and controlling tablet compression are discussed. The proposed automated tablet sampling strategy for in-line THz-TDS measurements proved to be feasible, enabling measurement speeds exceeding one tablet per second. While this strategy is specifically aimed at monitoring tablet compression, the developed algorithm is considered applicable in a broader range of automated THz-TDS measurement strategies.

Authors

Institutions

Publication Details

Journal
Chemical Engineering Science
Published
2025-06-07
DOI
https://doi.org/10.1016/j.ces.2025.121992
Citations
5
Primary Topic
Terahertz technology and applications
Type
article
Field-Weighted Citation Impact
3.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards real-time process monitoring and control of physical properties of tablets using terahertz spectroscopy

Thomas Kvistgaard Vilhelmsen, Moritz Anuschek, Anders Nielsen, Jukka Rantanen et al.
5 citations
Chemical Engineering Science
Terahertz technology and applications
3.65
article

Towards real-time process monitoring and control of physical properties of tablets using terahertz spectroscopy

Thomas Kvistgaard Vilhelmsen, Moritz Anuschek, Anders Nielsen, Jukka Rantanen, J. Axel Zeitler
article en
5 citations

Abstract

• The developed interface enables automated THz-TDS* measurements. • The developed algorithm sorts THz-TDS* data and detects outliers automatically. • 1 st and 2 nd step enable monitoring of physical attributes of pharmaceutical tablets. • Considerations for controlling pharmaceutical tableting using THz-TDS* The modernisation of pharmaceutical manufacturing requires the implementation of process analysers for real-time assessment of both the process and product quality, as part of a process analytical technology (PAT) strategy. To meet the high standards for data integrity, it is essential that process analysers are integrated with a suitable sampling interface and workflow to ensure a reproducible sample presentation and robust data processing strategy. Terahertz time-domain spectroscopy (THz-TDS) with a reflection setup has recently been introduced as a potential process analyser for a fast assessment of tablet thickness, porosity, and mass, simultaneously. This study explores the potential of automated THz-TDS measurements, including the testing of a novel sampling interface prototype coupled with an algorithm for data treatment to select and group tablet measurements from background noise. Sampling interface and algorithm reliably presented, identified, and subsequently analysed THz-TDS signals of tablets. Comparable model errors were observed between the in-line interface and non-automated off-line manual measurements, with root mean square errors (RMSEs) of ≤ 0.012 mm, ≤ 1.23 %, ≤ 1.3 mg for tablet thickness, porosity, and mass, respectively. Additionally, the potential for off-line calibration, ongoing model maintenance of the analytical procedure, and integration within a PAT framework for monitoring and controlling tablet compression are discussed. The proposed automated tablet sampling strategy for in-line THz-TDS measurements proved to be feasible, enabling measurement speeds exceeding one tablet per second. While this strategy is specifically aimed at monitoring tablet compression, the developed algorithm is considered applicable in a broader range of automated THz-TDS measurement strategies.

Chemical Engineering ScienceVol. 316
University of Copenhagen (DK), Novo Nordisk (Denmark) (DK), University of Cambridge (GB)
Novo Nordisk
Affordable and clean energy
Openalex Percentile: Top 7%
Terahertz technology and applications
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.