Finite element biomechanical evaluation of internal fixation methods for metacarpal shaft fractures under multiple factors

Metacarpal shaft fractures often require surgical correction of displacement, angulation, or rotational deformities to restore function. Kirschner wires (K-wires), plates, and intramedullary screw fixation each have advantages and limitations. However,inconsistent biomechanical evidence in existing studies has precluded definitive conclusions regarding the optimal fixation technique. This studycompared K-wires, plates, and intramedullary screw for metacarpal shaft fractures using finite element analysis (FEA). In normal bone, intramedullary screw matched plate stability under low loads but were inferior under high loads, K-wires performed poorest. In osteoporotic bone, intramedullary screw provided superior stability, stress distribution, and less stress shielding than plates or K-wires. These findings would offer valuable biomechanical insights for metacarpal fractures treatment.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-06-07
DOI
https://doi.org/10.1080/10255842.2025.2516766
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element biomechanical evaluation of internal fixation methods for metacarpal shaft fractures under multiple factors

Chunlin Zhang
Computer Methods in Biomechanics & Biomedical Engineering
Orthopedic Surgery and Rehabilitation
article

Finite element biomechanical evaluation of internal fixation methods for metacarpal shaft fractures under multiple factors

Chunlin Zhang
article en

Abstract

Metacarpal shaft fractures often require surgical correction of displacement, angulation, or rotational deformities to restore function. Kirschner wires (K-wires), plates, and intramedullary screw fixation each have advantages and limitations. However,inconsistent biomechanical evidence in existing studies has precluded definitive conclusions regarding the optimal fixation technique. This studycompared K-wires, plates, and intramedullary screw for metacarpal shaft fractures using finite element analysis (FEA). In normal bone, intramedullary screw matched plate stability under low loads but were inferior under high loads, K-wires performed poorest. In osteoporotic bone, intramedullary screw provided superior stability, stress distribution, and less stress shielding than plates or K-wires. These findings would offer valuable biomechanical insights for metacarpal fractures treatment.

Computer Methods in Biomechanics & Biomedical Engineering
Peking University (CN), Beijing Jishuitan Hospital (CN)
Climate action
Openalex Percentile: Top 77%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Finite element biomechanical evaluation of internal fixation methods for metacarpal shaft fractures under multiple factors — Chunlin Zhang · Computer Methods in Biomechanics & Biomedical Engineering (2025) | TGRS Research Map | TGRS