Conducting interslice stimulation for concurrent TMS-fMRI
A 10 Hz TMS interslice protocol is possible with minimal data contimination. A stimulation frequency faster than 10 Hz would require a shorter gap or shorter slice acquisition times. Further, stimulator intensity, slice orientation, and the number of TMS pulses affected data quality and are important considerations for researchers when setting up their own protocol.
Authors
- Catriona L. Scrivener (ORCID: https://orcid.org/0000-0002-9507-5587)
- Marta Correia (ORCID: https://orcid.org/0000-0002-3231-7040)
- Alexandra Woolgar (ORCID: https://orcid.org/0000-0002-8453-7424)
- Marius Mada (ORCID: https://orcid.org/0000-0002-9903-3835)
- J.B. Jackson
Institutions
- MRC Cognition and Brain Sciences Unit (GB)
- University of Cambridge (GB)
Publication Details
- Journal
- Journal of Neuroscience Methods
- Published
- 2025-06-06
- DOI
- https://doi.org/10.1016/j.jneumeth.2025.110513
- Citations
- 1
- Primary Topic
- Transcranial Magnetic Stimulation Studies
- Type
- article
- Field-Weighted Citation Impact
- 0.84