A novel smartphone-based nanozyme-enhanced electrochemical immunosensor for ultrasensitive direct detection of Staphylococcus aureus in milk and blood serum

A graphene quantum dot (GQD)-based nanozyme-enhanced electrochemical sensor was developed for the ultra-sensitive and rapid Staphylococcus aureus detection in PBS, undiluted milk, and blood serum. The S. aureus concentration for immunosensor calibration was electrochemically determined to be 1.24 × 10 9 CFU mL −1 (R 2 = 0.99), utilizing an innovative smartphone-based electrochemical device. Transmission electron (TEM) and atomic force (AFM) microscopy analyses of GQDs revealed uniform nanoparticles (8–10 nm) with surface heights of 2 nm and 21 nm at different scan areas. Fluorescence and Fourier transform infrared spectroscopy spectra showed an emission at 530 nm with an excitation wavelength of 485 nm, along with the presence of hydroxyl, carboxyl, and aromatic groups on the GQD surfaces. The maximum current peak for GQDs was obtained by optimizing electrochemical properties through amperometry at +0.9 V. The optimal signal intensity- and limit of detection (LOD)-based GQD concentrations were 0.0125, 0.5, and 1 mg mL −1 for PBS, undiluted milk, and blood serum, respectively. The optimal antibody concentration for S. aureus detection was 25 μg mL −1 , resulting in a 91 % amperometric suppression and a 94 % fluorescence quenching. The developed biosensor effectively detected S. aureus , with calculated LODs of 1, 4, and 344 CFU mL −1 in PBS, undiluted milk, and blood serum, respectively. TEM, AFM, and contact angle analyses confirmed S. aureus binding to the GQD-antibody bioconjugate, shifting surface height to 35 nm and contact angle from ~30° to ~65°. The immunosensor showed high specificity for S. aureus with minimal cross-reactivity to Listeria monocytogenes , Staphylococcus epidermidis , Enterococcus faecium, and Streptococcus pneumoniae .

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2025-06-06
DOI
https://doi.org/10.1016/j.sbsr.2025.100822
Citations
6
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel smartphone-based nanozyme-enhanced electrochemical immunosensor for ultrasensitive direct detection of Staphylococcus aureus in milk and blood serum

Sümeyra Savaş, Seyed Mohammad Taghi Gharibzahedi, Zeynep Altıntaş, Yalın Kılıç
6 citations
Sensing and Bio-Sensing Research
Advanced biosensing and bioanalysis techniques
4.84
article

A novel smartphone-based nanozyme-enhanced electrochemical immunosensor for ultrasensitive direct detection of Staphylococcus aureus in milk and blood serum

Sümeyra Savaş, Seyed Mohammad Taghi Gharibzahedi, Zeynep Altıntaş, Yalın Kılıç
article en
6 citations

Abstract

A graphene quantum dot (GQD)-based nanozyme-enhanced electrochemical sensor was developed for the ultra-sensitive and rapid Staphylococcus aureus detection in PBS, undiluted milk, and blood serum. The S. aureus concentration for immunosensor calibration was electrochemically determined to be 1.24 × 10 9 CFU mL −1 (R 2 = 0.99), utilizing an innovative smartphone-based electrochemical device. Transmission electron (TEM) and atomic force (AFM) microscopy analyses of GQDs revealed uniform nanoparticles (8–10 nm) with surface heights of 2 nm and 21 nm at different scan areas. Fluorescence and Fourier transform infrared spectroscopy spectra showed an emission at 530 nm with an excitation wavelength of 485 nm, along with the presence of hydroxyl, carboxyl, and aromatic groups on the GQD surfaces. The maximum current peak for GQDs was obtained by optimizing electrochemical properties through amperometry at +0.9 V. The optimal signal intensity- and limit of detection (LOD)-based GQD concentrations were 0.0125, 0.5, and 1 mg mL −1 for PBS, undiluted milk, and blood serum, respectively. The optimal antibody concentration for S. aureus detection was 25 μg mL −1 , resulting in a 91 % amperometric suppression and a 94 % fluorescence quenching. The developed biosensor effectively detected S. aureus , with calculated LODs of 1, 4, and 344 CFU mL −1 in PBS, undiluted milk, and blood serum, respectively. TEM, AFM, and contact angle analyses confirmed S. aureus binding to the GQD-antibody bioconjugate, shifting surface height to 35 nm and contact angle from ~30° to ~65°. The immunosensor showed high specificity for S. aureus with minimal cross-reactivity to Listeria monocytogenes , Staphylococcus epidermidis , Enterococcus faecium, and Streptococcus pneumoniae .

Sensing and Bio-Sensing ResearchVol. 49
İzmir University of Economics (TR), Dokuz Eylül University (TR), Hochschule für Angewandte Wissenschaften Kiel (DE), Bandırma Onyedi Eylül University (TR), Christian-Albrechts-Universität zu Kiel (DE)
Openalex Percentile: Top 5%
Advanced biosensing and bioanalysis techniques
4.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.