Refining resolution settings for analysis of dissolved organic matter in varied natural environments by Fourier‐transform ion cyclotron resonance mass spectrometry

Abstract Dissolved organic matter (DOM) is a major carbon reservoir and exhibits high chemo‐diversity and similarity. Fourier‐transform ion cyclotron resonance mass spectrometry (FT‐ICR MS) enables analysis of DOM due to its ultrahigh resolution at various field strengths. Capturing distinguishing features of DOM is especially challenging for lower resolution instruments. Here, we aim to refine resolution settings for various types of DOM. With a low‐field 7 Tesla (T) FT‐ICR MS, two strategies for tuning resolution were compared with free induction decay (FID) of 1–4 s: the initial mass to charge ( m / z ) ratio (A) and data size (B). Peak number rises then falls with data size; 16 M leads to loss of low‐mass compounds (< 220 m / z ). In further, the comparability of intensity‐weighted average parameters was evaluated, revealing that m / z , carbon number, H/C, O/C, aromatic index, and double bond equivalent have a coefficient of variation (CV) of < 3%; in contrast, the average number of heteroatoms—P (45%), N (21%), and S (22%)—shows considerable CV (%) with resolution, varying across samples. Furthermore, the minimum required value of resolution varies across samples, ranging from > 300,000 to > 500,000: it increases from riverine water to porewater, and then to seawater DOM, typically exhibiting abundant CHO, CHOS, and CHOP, respectively. For a 7T FT‐ICR MS, we propose tailored FID strategies: a 2‐s medium FID (resolution > 300,000) for regular DOM, a shorter FID (~ 1 s) for small metabolites with low initial m / z (~ 50–100), and a longer FID (resolution > 500,000) for heteroatom‐enriched DOM.

Authors

Institutions

Publication Details

Journal
Limnology and Oceanography Methods
Published
2025-06-06
DOI
https://doi.org/10.1002/lom3.10696
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Refining resolution settings for analysis of dissolved organic matter in varied natural environments by Fourier‐transform ion cyclotron resonance mass spectrometry

Shi-Ting Huang, Bin Jiang, Faming Wang, Pengran Guo et al.
Limnology and Oceanography Methods
Mass Spectrometry Techniques and Applications
article

Refining resolution settings for analysis of dissolved organic matter in varied natural environments by Fourier‐transform ion cyclotron resonance mass spectrometry

Shi-Ting Huang, Bin Jiang, Faming Wang, Pengran Guo, Jia-Chuan Pan, Zheng Gong, Ying Wu, Shuchai Gan, Yumei Song
article en

Abstract

Abstract Dissolved organic matter (DOM) is a major carbon reservoir and exhibits high chemo‐diversity and similarity. Fourier‐transform ion cyclotron resonance mass spectrometry (FT‐ICR MS) enables analysis of DOM due to its ultrahigh resolution at various field strengths. Capturing distinguishing features of DOM is especially challenging for lower resolution instruments. Here, we aim to refine resolution settings for various types of DOM. With a low‐field 7 Tesla (T) FT‐ICR MS, two strategies for tuning resolution were compared with free induction decay (FID) of 1–4 s: the initial mass to charge ( m / z ) ratio (A) and data size (B). Peak number rises then falls with data size; 16 M leads to loss of low‐mass compounds (< 220 m / z ). In further, the comparability of intensity‐weighted average parameters was evaluated, revealing that m / z , carbon number, H/C, O/C, aromatic index, and double bond equivalent have a coefficient of variation (CV) of < 3%; in contrast, the average number of heteroatoms—P (45%), N (21%), and S (22%)—shows considerable CV (%) with resolution, varying across samples. Furthermore, the minimum required value of resolution varies across samples, ranging from > 300,000 to > 500,000: it increases from riverine water to porewater, and then to seawater DOM, typically exhibiting abundant CHO, CHOS, and CHOP, respectively. For a 7T FT‐ICR MS, we propose tailored FID strategies: a 2‐s medium FID (resolution > 300,000) for regular DOM, a shorter FID (~ 1 s) for small metabolites with low initial m / z (~ 50–100), and a longer FID (resolution > 500,000) for heteroatom‐enriched DOM.

Limnology and Oceanography MethodsVol. 23(7)
Planetary Science Institute (US), Harvard University (US), Chinese Academy of Sciences (CN), Guangzhou Institute of Geochemistry (CN), Guangdong Academy of Sciences (CN), South China Botanical Garden (CN), East China Normal University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province, Youth Innovation Promotion Association of the Chinese Academy of Sciences, Alliance of International Science Organizations, National Key Research and Development Program of China, Youth Innovation Promotion Association
Life below water
Openalex Percentile: Top 88%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.