A Microdosimetric Dose Response Model for Monoenergetic Ions and Doses Relevant for Space Radiation Carcinogenesis

The radiation environment in space consists of a complex mixture of particles and energies that are characteristically different from any natural Earth radiation source. Projections of space radiation cancer risk are obtained by scaling or adjusting epidemiological models derived from terrestrially exposed cohorts to account for differences in radiation quality, dose rate, and other factors. Radiation quality and dose-rate effects introduce significant uncertainty, thereby obfuscating risk communication and hindering the ability to evaluate the efficacy of mitigation strategies such as medical countermeasures. Space radiation quality factors are developed through a multi-step process that requires computational models and experimental data. The first step in this process involves developing dose-response models and fitting them to data from ground-based experiments involving acute irradiation of animals or cells. There is limited ground-based data compared to the range of ions and energies found in space; thus, dose-response models must be able to reproduce available data and predict responses where no data exist. This work focuses on developing a microdosimetric (μD) dose-response model applicable to experimental datasets relevant to space radiation cancer induction. Three experimental datasets, encompassing murine Harderian gland tumorigenesis and chromosome aberrations in human skin fibroblasts and blood lymphocytes, are utilized to demonstrate key features and overall performance of the μD model. The model generates non-linear dose-responses and can predict charge and energy dependence observed in experimental data without the use of empirical functions or corrections. Additionally, the μD model identifies the critical microscopic target population and target size that drive the observed biological effects.

Authors

Institutions

Publication Details

Journal
Radiation Research
Published
2025-06-06
DOI
https://doi.org/10.1667/rade-25-00021.1
Citations
4
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
6.07
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Microdosimetric Dose Response Model for Monoenergetic Ions and Doses Relevant for Space Radiation Carcinogenesis

Tony C. Slaba, Shirin Rahmanian, Floriane Poignant
4 citations
Radiation Research
Radiation Therapy and Dosimetry
6.07
article

A Microdosimetric Dose Response Model for Monoenergetic Ions and Doses Relevant for Space Radiation Carcinogenesis

Tony C. Slaba, Shirin Rahmanian, Floriane Poignant
article en
4 citations

Abstract

The radiation environment in space consists of a complex mixture of particles and energies that are characteristically different from any natural Earth radiation source. Projections of space radiation cancer risk are obtained by scaling or adjusting epidemiological models derived from terrestrially exposed cohorts to account for differences in radiation quality, dose rate, and other factors. Radiation quality and dose-rate effects introduce significant uncertainty, thereby obfuscating risk communication and hindering the ability to evaluate the efficacy of mitigation strategies such as medical countermeasures. Space radiation quality factors are developed through a multi-step process that requires computational models and experimental data. The first step in this process involves developing dose-response models and fitting them to data from ground-based experiments involving acute irradiation of animals or cells. There is limited ground-based data compared to the range of ions and energies found in space; thus, dose-response models must be able to reproduce available data and predict responses where no data exist. This work focuses on developing a microdosimetric (μD) dose-response model applicable to experimental datasets relevant to space radiation cancer induction. Three experimental datasets, encompassing murine Harderian gland tumorigenesis and chromosome aberrations in human skin fibroblasts and blood lymphocytes, are utilized to demonstrate key features and overall performance of the μD model. The model generates non-linear dose-responses and can predict charge and energy dependence observed in experimental data without the use of empirical functions or corrections. Additionally, the μD model identifies the critical microscopic target population and target size that drive the observed biological effects.

Radiation ResearchVol. 204(2)
Langley Research Center (US), Analytical Mechanics Associates (United States) (US)
Good health and well-being
Openalex Percentile: Top 4%
Radiation Therapy and Dosimetry
6.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.