Determining errors in force measurements for colloids close to contact

Abstract Due to diffraction patterns in light microscopy, the overlapping of colloid images introduces minor errors in determining particle positions, which affecting the accuracy of observing interactions between colloids near contact. This study quantitatively investigates the errors arising from the overlapping effect in force measurements between two closely positioned colloids using digital video microscopy (DVM). For this aim, computer simulations were conducted to obtain the positions of two optically trapped colloids interacting based on a force model and particle images were generated as a time series using experimental particle intensity profiles for two different particle sizes. These generated images were analyzed using tracking algorithms from the literature and the interaction forces were extracted and compared with theoretical force values. The results demonstrated that diffraction patterns significantly influence the accuracy of particle position detection and interaction force calculations. Large diffraction patterns and intensity fluctuations in an image introduce significant errors. However, these errors can become significantly smaller in the presence of large forces and may therefore be considered negligible.

Authors

Institutions

Publication Details

Journal
Applied Physics A
Published
2025-06-06
DOI
https://doi.org/10.1007/s00339-025-08668-8
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining errors in force measurements for colloids close to contact

Harun Yücel
4 links
Applied Physics A
Microfluidic and Bio-sensing Technologies
article

Determining errors in force measurements for colloids close to contact

Harun Yücel
article en

Abstract

Abstract Due to diffraction patterns in light microscopy, the overlapping of colloid images introduces minor errors in determining particle positions, which affecting the accuracy of observing interactions between colloids near contact. This study quantitatively investigates the errors arising from the overlapping effect in force measurements between two closely positioned colloids using digital video microscopy (DVM). For this aim, computer simulations were conducted to obtain the positions of two optically trapped colloids interacting based on a force model and particle images were generated as a time series using experimental particle intensity profiles for two different particle sizes. These generated images were analyzed using tracking algorithms from the literature and the interaction forces were extracted and compared with theoretical force values. The results demonstrated that diffraction patterns significantly influence the accuracy of particle position detection and interaction force calculations. Large diffraction patterns and intensity fluctuations in an image introduce significant errors. However, these errors can become significantly smaller in the presence of large forces and may therefore be considered negligible.

Applied Physics AVol. 131(7)
Bayburt University (TR)
Bayburt Üniversitesi
Openalex Percentile: Top 88%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.