Pedicle Screw Pitch Design: 3D-Printed Injectable Bone Substitute for Spinal Osteoporosis

This study aims to determine the effect of pitch variations on pedicle screws for spinal osteoporosis applications. Five variations of pedicle screw pitch (1.75; 2.00; 2.25; 2.50; 2.75 mm) were printed with filaments made of Polylactide Acid (PLA) using a 3D-printing with the Fused Deposition Modelling (FDM) technique. The materials mixed to make the Injectable Bone Substitute (IBS) paste injected into the pedicle screw were Hydroxyapatite (HA), gelatin, hydroxypropyl methylcellulose (HMPC), and alendronate. The pull-out test results showed that the pedicle screw with a pitch of 2.75 mm had the highest value, namely 24.568 ± 0.431 N for screws without IBS paste and 44.814 ± 0.939 N for screws with IBS paste. The results showed that the pedicle screw with the larger pitch had better pull-out and torsional test values, but the larger pitch made the characterization of the bending test decreased. Thus, it can be stated that a pedicle screw with a large pitch is suitable for spinal osteoporosis applications.

Authors

Institutions

Publication Details

Journal
Journal of biomimetics, biomaterials and biomedical engineering
Published
2025-06-06
DOI
https://doi.org/10.4028/p-2pmxda
Citations
1
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pedicle Screw Pitch Design: 3D-Printed Injectable Bone Substitute for Spinal Osteoporosis

Frazna Parastuti, Aminatun Aminatun, Dyah Hikmawati, Sakinato Mazidda et al.
1 citations
Journal of biomimetics, biomaterials and biomedical engineering
Spine and Intervertebral Disc Pathology
1.47
article

Pedicle Screw Pitch Design: 3D-Printed Injectable Bone Substitute for Spinal Osteoporosis

Frazna Parastuti, Aminatun Aminatun, Dyah Hikmawati, Sakinato Mazidda, Siswanto Siswanto, Ghassani Nurbaningtyas, Atin Asna Octavia
article en
1 citations

Abstract

This study aims to determine the effect of pitch variations on pedicle screws for spinal osteoporosis applications. Five variations of pedicle screw pitch (1.75; 2.00; 2.25; 2.50; 2.75 mm) were printed with filaments made of Polylactide Acid (PLA) using a 3D-printing with the Fused Deposition Modelling (FDM) technique. The materials mixed to make the Injectable Bone Substitute (IBS) paste injected into the pedicle screw were Hydroxyapatite (HA), gelatin, hydroxypropyl methylcellulose (HMPC), and alendronate. The pull-out test results showed that the pedicle screw with a pitch of 2.75 mm had the highest value, namely 24.568 ± 0.431 N for screws without IBS paste and 44.814 ± 0.939 N for screws with IBS paste. The results showed that the pedicle screw with the larger pitch had better pull-out and torsional test values, but the larger pitch made the characterization of the bending test decreased. Thus, it can be stated that a pedicle screw with a large pitch is suitable for spinal osteoporosis applications.

Journal of biomimetics, biomaterials and biomedical engineeringVol. 68
National Taiwan University of Science and Technology (TW), Universitas Airlangga (ID)
Openalex Percentile: Top 19%
Spine and Intervertebral Disc Pathology
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pedicle Screw Pitch Design: 3D-Printed Injectable Bone Substitute for Spinal Osteoporosis — Frazna Parastuti, Aminatun Aminatun, et al. · Journal of biomimetics, biomaterials and biomedical engineering (2025) | TGRS Research Map | TGRS