Application and Performance Improvement of an Optical Power Stabilization System Based on MEMS-LCVR in a SERF Atomic Magnetometer

A stabilization method utilizing MEMS technology combined with a liquid crystal variable retarder (LCVR) was developed to enhance fiber laser output power stability and was applied to a spin-exchange relaxation-free (SERF) atomic magnetometer. Comparative experiments demonstrated that the unstabilized laser output exhibited 2.8% power fluctuations over a 500 s period, while the stabilized laser reduced this to 0.2%. Spectral density analysis confirmed suppressed frequency-domain fluctuations, indicating improved robustness against disturbances. Furthermore, the stabilized laser also reduced optical noise in SERF magnetometry, achieving a sensitivity of 19.2fT/Hz1/2. These results validate that the method optimizes both time- and frequency-domain performance, thereby advancing high-precision SERF magnetometry.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2025-06-06
DOI
https://doi.org/10.3390/photonics12060573
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application and Performance Improvement of an Optical Power Stabilization System Based on MEMS-LCVR in a SERF Atomic Magnetometer

Wenfei Zhang, Jiping Yang, Yueyang Zhai, Yitong Li et al.
1 links
Photonics
Atomic and Subatomic Physics Research
article

Application and Performance Improvement of an Optical Power Stabilization System Based on MEMS-LCVR in a SERF Atomic Magnetometer

Wenfei Zhang, Jiping Yang, Yueyang Zhai, Yitong Li, Ying Liu
article en

Abstract

A stabilization method utilizing MEMS technology combined with a liquid crystal variable retarder (LCVR) was developed to enhance fiber laser output power stability and was applied to a spin-exchange relaxation-free (SERF) atomic magnetometer. Comparative experiments demonstrated that the unstabilized laser output exhibited 2.8% power fluctuations over a 500 s period, while the stabilized laser reduced this to 0.2%. Spectral density analysis confirmed suppressed frequency-domain fluctuations, indicating improved robustness against disturbances. Furthermore, the stabilized laser also reduced optical noise in SERF magnetometry, achieving a sensitivity of 19.2fT/Hz1/2. These results validate that the method optimizes both time- and frequency-domain performance, thereby advancing high-precision SERF magnetometry.

PhotonicsVol. 12(6)
Shandong University of Technology (CN), Hefei University (CN), Beihang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 90%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.