Auto-Segmentation and Auto-Planning in Automated Radiotherapy for Prostate Cancer

<b>Objective:</b> The objective of this study was to develop and assess the clinical feasibility of auto-segmentation and auto-planning methodologies for automated radiotherapy in prostate cancer. <b>Methods</b>: A total of 166 patients were used to train a 3D Unet model for segmentation of the gross tumor volume (GTV), clinical tumor volume (CTV), nodal CTV (CTVnd), and organs at risk (OARs). Performance was assessed by the Dice similarity coefficient (<i>DSC</i>), the <i>Recall</i>, <i>Precision</i>, <i>Volume Ratio (VR)</i>, the 95% Hausdorff distance (<i>HD95</i>%), and the volumetric revision degree (<i>VRD</i>). An auto-planning network based on a 3D Unet was trained on 77 treatment plans derived from the 166 patients. Dosimetric differences and clinical acceptability of the auto-plans were studied. The effect of OAR editing on dosimetry was also evaluated. <b>Results</b>: On an independent set of 50 cases, the auto-segmentation process took 1 min 20 s per case. The <i>DSCs</i> for GTV, CTV, and CTVnd were 0.87, 0.88, and 0.82, respectively, with <i>VRD</i>s ranging from 0.09 to 0.14. The segmentation of OARs demonstrated high accuracy (<i>DSC</i> ≥ 0.83, <i>Recall/Precision</i> ≈ 1.0). The auto-planning process required 1-3 optimization iterations for 50%, 40%, and 10% of cases, respectively, and exhibited significant better conformity (<i>p</i> ≤ 0.01) and OAR sparing (<i>p</i> ≤ 0.03) while maintaining comparable target coverage. Only 6.7% of auto-plans were deemed unacceptable compared to 20% of manual plans, with 75% of auto-plans considered superior. Notably, the editing of OARs had no significant impact on doses. <b>Conclusions:</b> The accuracy of auto-segmentation is comparable to that of manual segmentation, and the auto-planning offers equivalent or better OAR protection, meeting the requirements of online automated radiotherapy and facilitating its clinical application.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-06-06
DOI
https://doi.org/10.3390/bioengineering12060620
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
3.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Auto-Segmentation and Auto-Planning in Automated Radiotherapy for Prostate Cancer

Lecheng Jia, Liru He, Sijuan Huang, Li Chen et al.
2 citations
Bioengineering
Advanced Radiotherapy Techniques
3.77
article

Auto-Segmentation and Auto-Planning in Automated Radiotherapy for Prostate Cancer

Lecheng Jia, Liru He, Sijuan Huang, Li Chen, Guangyu Wang, Ting Song, Ruiqi Liu, Xin Yang, Yang Liu, Xiaoyan Huang, Qian Cao, Jingheng Wu, Xi Lin
article en
2 citations

Abstract

<b>Objective:</b> The objective of this study was to develop and assess the clinical feasibility of auto-segmentation and auto-planning methodologies for automated radiotherapy in prostate cancer. <b>Methods</b>: A total of 166 patients were used to train a 3D Unet model for segmentation of the gross tumor volume (GTV), clinical tumor volume (CTV), nodal CTV (CTVnd), and organs at risk (OARs). Performance was assessed by the Dice similarity coefficient (<i>DSC</i>), the <i>Recall</i>, <i>Precision</i>, <i>Volume Ratio (VR)</i>, the 95% Hausdorff distance (<i>HD95</i>%), and the volumetric revision degree (<i>VRD</i>). An auto-planning network based on a 3D Unet was trained on 77 treatment plans derived from the 166 patients. Dosimetric differences and clinical acceptability of the auto-plans were studied. The effect of OAR editing on dosimetry was also evaluated. <b>Results</b>: On an independent set of 50 cases, the auto-segmentation process took 1 min 20 s per case. The <i>DSCs</i> for GTV, CTV, and CTVnd were 0.87, 0.88, and 0.82, respectively, with <i>VRD</i>s ranging from 0.09 to 0.14. The segmentation of OARs demonstrated high accuracy (<i>DSC</i> ≥ 0.83, <i>Recall/Precision</i> ≈ 1.0). The auto-planning process required 1-3 optimization iterations for 50%, 40%, and 10% of cases, respectively, and exhibited significant better conformity (<i>p</i> ≤ 0.01) and OAR sparing (<i>p</i> ≤ 0.03) while maintaining comparable target coverage. Only 6.7% of auto-plans were deemed unacceptable compared to 20% of manual plans, with 75% of auto-plans considered superior. Notably, the editing of OARs had no significant impact on doses. <b>Conclusions:</b> The accuracy of auto-segmentation is comparable to that of manual segmentation, and the auto-planning offers equivalent or better OAR protection, meeting the requirements of online automated radiotherapy and facilitating its clinical application.

BioengineeringVol. 12(6)
Sun Yat-sen University (CN), Chinese Academy of Sciences (CN), Sun Yat-sen Memorial Hospital (CN), United Imaging Healthcare (China) (CN), Sun Yat-sen University Cancer Center (CN), Southern Medical University (CN)
Beijing Xisike Clinical Oncology Research Foundation
Good health and well-being
Openalex Percentile: Top 7%
Advanced Radiotherapy Techniques
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.