On the Use of 4D-PET/CT for the Safe SBRT Re-Irradiation of Central Lung Recurrence Within Radiation-Induced Fibrosis: A Clinical Case

<b>Background:</b> The re-irradiation of centrally located lung tumors poses substantial risks due to prior dose exposure and proximity to critical structures. Accurate target delineation is crucial to minimize toxicity and ensure tumor coverage. Four-dimensional positron emission tomography/computed tomography (4D-PET/CT) integrates respiratory motion and metabolic data, offering improved delineation over static imaging. Its clinical utility in re-irradiation remains under-reported. <b>Methods:</b> A 67-year-old male presented with the central recurrence of squamous cell carcinoma in the right upper lobe, embedded in radiation-induced fibrosis, following prior chemoradiotherapy. Delineation using static PET underestimated tumor motion. A 4D-PET/CT-guided Stereotactic Body Radiation Therapy (SBRT) plan was developed with a prescription of 60 Gy in eight fractions. A comparative plan using static PET was generated to assess the dosimetric differences. <b>Results:</b> The internal target volume (ITV) from 4D-PET/CT was nearly double the size of the GTV from static PET, with a 5.1 mm discrepancy in the craniocaudal axis. The 4D-PET-based plan achieved 95.0% PTV coverage, while the static PET-based plan covered only 61.7%, illustrating the risk of underdosage without motion-resolved imaging. The patient completed the treatment without acute or late toxicity and showed a sustained metabolic response at one year (SUVmax from 13.4 to 5.8). <b>Conclusions:</b> This case demonstrates the clinical value of 4D-PET/CT in the SBRT re-irradiation of centrally located lung tumors, particularly in fibrotic regions where anatomical imaging is insufficient. It enabled accurate delineation, improved dosimetric coverage, and safe, effective retreatment. These findings support its integration into planning for complex thoracic re-irradiation.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-06-06
DOI
https://doi.org/10.3390/jcm14124015
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
3.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Use of 4D-PET/CT for the Safe SBRT Re-Irradiation of Central Lung Recurrence Within Radiation-Induced Fibrosis: A Clinical Case

Paul Retif, Abdourahamane Djibo Sidikou, Mohamed N. Saleh, Romain Letellier et al.
2 citations
Journal of Clinical Medicine
Advanced Radiotherapy Techniques
3.77
article

On the Use of 4D-PET/CT for the Safe SBRT Re-Irradiation of Central Lung Recurrence Within Radiation-Induced Fibrosis: A Clinical Case

Paul Retif, Abdourahamane Djibo Sidikou, Mohamed N. Saleh, Romain Letellier, Emilie Verrecchia‐Ramos, Estelle Pfletschinger, Fabian Taesch, Xavier Michel, Anwar Al Salah, Sinan Ben-Mahmoud
article en
2 citations

Abstract

<b>Background:</b> The re-irradiation of centrally located lung tumors poses substantial risks due to prior dose exposure and proximity to critical structures. Accurate target delineation is crucial to minimize toxicity and ensure tumor coverage. Four-dimensional positron emission tomography/computed tomography (4D-PET/CT) integrates respiratory motion and metabolic data, offering improved delineation over static imaging. Its clinical utility in re-irradiation remains under-reported. <b>Methods:</b> A 67-year-old male presented with the central recurrence of squamous cell carcinoma in the right upper lobe, embedded in radiation-induced fibrosis, following prior chemoradiotherapy. Delineation using static PET underestimated tumor motion. A 4D-PET/CT-guided Stereotactic Body Radiation Therapy (SBRT) plan was developed with a prescription of 60 Gy in eight fractions. A comparative plan using static PET was generated to assess the dosimetric differences. <b>Results:</b> The internal target volume (ITV) from 4D-PET/CT was nearly double the size of the GTV from static PET, with a 5.1 mm discrepancy in the craniocaudal axis. The 4D-PET-based plan achieved 95.0% PTV coverage, while the static PET-based plan covered only 61.7%, illustrating the risk of underdosage without motion-resolved imaging. The patient completed the treatment without acute or late toxicity and showed a sustained metabolic response at one year (SUVmax from 13.4 to 5.8). <b>Conclusions:</b> This case demonstrates the clinical value of 4D-PET/CT in the SBRT re-irradiation of centrally located lung tumors, particularly in fibrotic regions where anatomical imaging is insufficient. It enabled accurate delineation, improved dosimetric coverage, and safe, effective retreatment. These findings support its integration into planning for complex thoracic re-irradiation.

Journal of Clinical MedicineVol. 14(12)
Centre National de la Recherche Scientifique (FR), Centre de Recherche en Automatique de Nancy (FR), Centre Hospitalier Régional de Metz-Thionville (FR), Université de Lorraine (FR)
Good health and well-being
Openalex Percentile: Top 7%
Advanced Radiotherapy Techniques
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.