Nanoflow Size Exclusion Chromatography–Native Mass Spectrometry of Intact Proteoforms and Protein Complexes

Native size-exclusion chromatography (SEC) coupled with native mass spectrometry (nMS) enables the characterization of proteins and protein complexes by combining liquid-phase separation (SEC) and mass measurement (nMS). This approach allows for an increase in the throughput of nMS experiments, reduces the bias that may be present due to the co-ionization of oligomers, and facilitates online sample buffer exchange. Conventional SEC-nMS uses volatile buffers and relatively wide-diameter columns (e.g., ≥1 mm), with flow rates in the tens of μL/min. To ionize sample components under this flow regime, relatively harsh electrospray ionization (ESI) desolvation conditions are needed, potentially resulting in protein dissociation/denaturation. Additionally, relatively large amounts of samples are required (several μgs). Herein, we describe the development of a nanoflow SEC-nMS method using 200 μm I.D. columns, operated at 500 nL min<sup>-1</sup>. This approach enables buffer exchange, oligomer separation, and mild ionization conditions (e.g., without the assistance of heated gas flow or temperature). Compared to microflow (1 mm I.D. column), the nanoflow method achieved a 4-fold increase in MS peak intensity, despite using a sample 20 times less concentrated (0.05 mg mL<sup>-1</sup> for nanoflow vs 1 mg mL<sup>-1</sup> for microflow). Furthermore, we evaluated the impact of three injection approaches on sensitivity and separation efficiency: large volume (1 μL), nanovolume (50 nL), and online mixed-bed ion-exchange capillary trap injection. To demonstrate its performance and applicability for sample-limited analysis, the final method using nanovolume injection was applied to several model proteins, protein complexes and a urine sample from a pregnant donor.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-06-06
DOI
https://doi.org/10.1021/acs.analchem.5c01019
Citations
5
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
3.78

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanoflow Size Exclusion Chromatography–Native Mass Spectrometry of Intact Proteoforms and Protein Complexes

Alina Astefanei, Andrea Gargano, Vasilis Tseliou, Ziran Zhai et al.
5 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
3.78
article

Nanoflow Size Exclusion Chromatography–Native Mass Spectrometry of Intact Proteoforms and Protein Complexes

Alina Astefanei, Andrea Gargano, Vasilis Tseliou, Ziran Zhai, Francesco G. Mutti, Annika A. M. van der Zon, Thomas Holmark
article en
5 citations

Abstract

Native size-exclusion chromatography (SEC) coupled with native mass spectrometry (nMS) enables the characterization of proteins and protein complexes by combining liquid-phase separation (SEC) and mass measurement (nMS). This approach allows for an increase in the throughput of nMS experiments, reduces the bias that may be present due to the co-ionization of oligomers, and facilitates online sample buffer exchange. Conventional SEC-nMS uses volatile buffers and relatively wide-diameter columns (e.g., ≥1 mm), with flow rates in the tens of μL/min. To ionize sample components under this flow regime, relatively harsh electrospray ionization (ESI) desolvation conditions are needed, potentially resulting in protein dissociation/denaturation. Additionally, relatively large amounts of samples are required (several μgs). Herein, we describe the development of a nanoflow SEC-nMS method using 200 μm I.D. columns, operated at 500 nL min<sup>-1</sup>. This approach enables buffer exchange, oligomer separation, and mild ionization conditions (e.g., without the assistance of heated gas flow or temperature). Compared to microflow (1 mm I.D. column), the nanoflow method achieved a 4-fold increase in MS peak intensity, despite using a sample 20 times less concentrated (0.05 mg mL<sup>-1</sup> for nanoflow vs 1 mg mL<sup>-1</sup> for microflow). Furthermore, we evaluated the impact of three injection approaches on sensitivity and separation efficiency: large volume (1 μL), nanovolume (50 nL), and online mixed-bed ion-exchange capillary trap injection. To demonstrate its performance and applicability for sample-limited analysis, the final method using nanovolume injection was applied to several model proteins, protein complexes and a urine sample from a pregnant donor.

Analytical ChemistryVol. 97(23)
Amsterdam University of Applied Sciences (NL), University of Amsterdam (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek, China Scholarship Council
Reduced inequalities
Openalex Percentile: Top 6%
Mass Spectrometry Techniques and Applications
3.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.