Comparison of clinical outcomes and capsular bag stability between plate-haptic and C-loop haptic toric IOLs in cataract eyes

ObjectiveTo compare the refractive outcomes and rotational stability between a plate-haptic toric intraocular lens (IOL) and a C-loop haptic toric IOL in cataract eyes with corneal astigmatism.MethodsThis was a prospective, randomised, controlled study. 72 patients (72 eyes) with cataracts and corneal astigmatism were randomly divided into 2 groups (Group A: C-loop haptic; Group B: plate-haptic) and underwent phacoemulsification combined with toric IOL implantation at Changzhou Third People's Hospital. The uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BDVA) and residual astigmatism (RAS) were assessed at 1 day, 1 week, 1 month, 3 months postoperatively, while the degree of toric IOL rotation was recorded at 1 week, 1 month, 3 months postoperatively. The correlation between IOL rotation and RAS, intraocular pressure (IOP), axial length (AL), anterior chamber depth (ACD), and white-to-white (WTW) distance was analyzed. Patient satisfaction was evaluated in both groups 3 months postoperatively. Independent sample <i>t</i>-test was used for comparison between the two groups, and repeated measures analysis of variance (ANOVA) was employed to assess changes in IOL rotation, RAS and visual acuity at various postoperative time points. Pearson correlation analysis was used to assess the relationships between continuous variables.ResultsA total of 72 eyes (36 per group) were included with no significant difference in patient characteristics between the two groups. The average postoperative degree of toric IOL rotation in Group A at 1-week, 1-month, and 3-month was greater than that in Group B (8.38 ± 4.19°vs 4.45 ± 2.40°, 7.78 ± 6.87°vs 3.95 ± 2.14°, and 8.23 ± 4.72°vs 4.09 ± 2.12°, respectively, all <i>P</i> < 0.05). Postoperative RAS and spherical equivalent (SE) were better in Group B than Group A (all <i>P</i> < 0.05). More patients in Group B achieved RAS within 0.50D than in Group A (23 vs 14). RAS was positively correlated with IOL rotation in both groups. Patients in Group B achieved a better UDVA than in Group A, whereas no statistical difference in BDVA was found between groups. No significant correlations were found between toric IOL rotation and IOP, AL, ACD, and WTW distance either in Group A or Group B (all <i>P </i>><i> </i>0.05). Patient satisfaction was referred as high or very high by 75.0% of patients in Group B compared to 50.0% in Group A. More patients in Group B gained distance spectacle independence than Group A (20 vs 10). No eye-threatening complications were observed intraoperatively or postoperatively. No patients required IOL repositioning during follow-up.ConclusionsThe plate-haptic toric IOL demonstrated superior rotational stability and astigmatism correction than C-loop haptic toric IOL within 3 months postoperatively, which implied that the plate-haptic toric IOL might be a better choice for patients with cataract and corneal astigmatism.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2025-06-06
DOI
https://doi.org/10.1177/11206721251349041
Citations
1
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
1.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of clinical outcomes and capsular bag stability between plate-haptic and C-loop haptic toric IOLs in cataract eyes

Guohua Deng, Zhinan Liu, Dong Zhou, Yi Jiang et al.
1 citations
European Journal of Ophthalmology
Intraocular Surgery and Lenses
1.71
article

Comparison of clinical outcomes and capsular bag stability between plate-haptic and C-loop haptic toric IOLs in cataract eyes

Guohua Deng, Zhinan Liu, Dong Zhou, Yi Jiang, Jun Zhang, Xin Gao
article en
1 citations

Abstract

ObjectiveTo compare the refractive outcomes and rotational stability between a plate-haptic toric intraocular lens (IOL) and a C-loop haptic toric IOL in cataract eyes with corneal astigmatism.MethodsThis was a prospective, randomised, controlled study. 72 patients (72 eyes) with cataracts and corneal astigmatism were randomly divided into 2 groups (Group A: C-loop haptic; Group B: plate-haptic) and underwent phacoemulsification combined with toric IOL implantation at Changzhou Third People's Hospital. The uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BDVA) and residual astigmatism (RAS) were assessed at 1 day, 1 week, 1 month, 3 months postoperatively, while the degree of toric IOL rotation was recorded at 1 week, 1 month, 3 months postoperatively. The correlation between IOL rotation and RAS, intraocular pressure (IOP), axial length (AL), anterior chamber depth (ACD), and white-to-white (WTW) distance was analyzed. Patient satisfaction was evaluated in both groups 3 months postoperatively. Independent sample <i>t</i>-test was used for comparison between the two groups, and repeated measures analysis of variance (ANOVA) was employed to assess changes in IOL rotation, RAS and visual acuity at various postoperative time points. Pearson correlation analysis was used to assess the relationships between continuous variables.ResultsA total of 72 eyes (36 per group) were included with no significant difference in patient characteristics between the two groups. The average postoperative degree of toric IOL rotation in Group A at 1-week, 1-month, and 3-month was greater than that in Group B (8.38 ± 4.19°vs 4.45 ± 2.40°, 7.78 ± 6.87°vs 3.95 ± 2.14°, and 8.23 ± 4.72°vs 4.09 ± 2.12°, respectively, all <i>P</i> < 0.05). Postoperative RAS and spherical equivalent (SE) were better in Group B than Group A (all <i>P</i> < 0.05). More patients in Group B achieved RAS within 0.50D than in Group A (23 vs 14). RAS was positively correlated with IOL rotation in both groups. Patients in Group B achieved a better UDVA than in Group A, whereas no statistical difference in BDVA was found between groups. No significant correlations were found between toric IOL rotation and IOP, AL, ACD, and WTW distance either in Group A or Group B (all <i>P </i>><i> </i>0.05). Patient satisfaction was referred as high or very high by 75.0% of patients in Group B compared to 50.0% in Group A. More patients in Group B gained distance spectacle independence than Group A (20 vs 10). No eye-threatening complications were observed intraoperatively or postoperatively. No patients required IOL repositioning during follow-up.ConclusionsThe plate-haptic toric IOL demonstrated superior rotational stability and astigmatism correction than C-loop haptic toric IOL within 3 months postoperatively, which implied that the plate-haptic toric IOL might be a better choice for patients with cataract and corneal astigmatism.

European Journal of OphthalmologyVol. 35(6)
Changzhou Third People's Hospital (CN), Nanjing Medical University (CN)
Openalex Percentile: Top 17%
Intraocular Surgery and Lenses
1.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.