Super-Resolution Confocal Microscopy Enabled by Fluorescence Intensity Ratio Encoding and Difference

We present fluorescence intensity ratio encoding and difference (FIRED) microscopy, an innovative far-field super-resolution method capable of surpassing the optical diffraction barrier in fluorescence microscopy. By dynamically modulating the effective excitation spot in an optimized confocal microscope, this method uses the unique ratio of fluorescence intensity between two images generated via distinct excitation light paths to derive a weight matrix. The weight matrix encodes the original confocal image to generate the super-resolution FIRE image. Subsequent differential modulation between this FIRE image and a weighted confocal image produces the final FIRED image, suppressing artifacts while enhancing both resolution and background contrast. Experimental validations confirmed that FIRED achieves a resolution improvement of up to 4-fold over conventional confocal microscopy, attaining a lateral resolution of 71.2 nm. Additionally, FIRED exhibits an enhanced signal-to-background ratio, positioning it as a robust tool for pushing the limits of confocal microscopy in biological and materials science applications.

Authors

Institutions

Publication Details

Journal
Nano Letters
Published
2025-06-06
DOI
https://doi.org/10.1021/acs.nanolett.5c02339
Citations
3
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
4.90

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Super-Resolution Confocal Microscopy Enabled by Fluorescence Intensity Ratio Encoding and Difference

Dongyi Liu, Xuegang Zhu, Luwei Wang, Yue Chen et al.
3 citations
Nano Letters
Advanced Fluorescence Microscopy Techniques
4.90
article

Super-Resolution Confocal Microscopy Enabled by Fluorescence Intensity Ratio Encoding and Difference

Dongyi Liu, Xuegang Zhu, Luwei Wang, Yue Chen, Liwei Liu, Qinglin Chen, Xiaoyu Weng, Junle Qu
article en
3 citations

Abstract

We present fluorescence intensity ratio encoding and difference (FIRED) microscopy, an innovative far-field super-resolution method capable of surpassing the optical diffraction barrier in fluorescence microscopy. By dynamically modulating the effective excitation spot in an optimized confocal microscope, this method uses the unique ratio of fluorescence intensity between two images generated via distinct excitation light paths to derive a weight matrix. The weight matrix encodes the original confocal image to generate the super-resolution FIRE image. Subsequent differential modulation between this FIRE image and a weighted confocal image produces the final FIRED image, suppressing artifacts while enhancing both resolution and background contrast. Experimental validations confirmed that FIRED achieves a resolution improvement of up to 4-fold over conventional confocal microscopy, attaining a lateral resolution of 71.2 nm. Additionally, FIRED exhibits an enhanced signal-to-background ratio, positioning it as a robust tool for pushing the limits of confocal microscopy in biological and materials science applications.

Nano LettersVol. 25(24)
Shenzhen University (CN), Photonics (United States) (US)
National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 5%
Advanced Fluorescence Microscopy Techniques
4.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.