Glass Fiber Interfaced Special Rolling Circle Amplification for Multiplexed Protein Detection with Paper Strip Digital Readouts

Point-of-care testing (POCT) for proteins faces challenges, including limited sensitivity and multiplexing capabilities. The recently developed minimum secondary structured rolling circle amplification (MSS-RCA) promised POCT with desirable sensitivity in nucleic acid detection under isothermal conditions, but with a long assay time. This study integrates the 5' specific enzymatic activity of T7 exonuclease with the high-speed template elongation ability of MSS-RCA in a one-pot system to establish the dual amplification T7-MSSRCA detection platform. T7-MSSRCA employed a specialized reporter modified with human chorionic gonadotrophin (hCG) molecules for signal output on hCG test strips, which could be measured by a lateral flow assay (LFA) analyzer. The integration of T7-MSSRCA with glass fiber interfaced immunoassays enabled multiplexed detection of low-abundance protein targets (α-synuclein, IL-6, TNF-α, and IFN-γ) at subpicogram levels in serum samples of Parkinson's disease with high specificity and accuracy, promising its application in biomarker identification of chronic diseases.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-06-06
DOI
https://doi.org/10.1021/acssensors.5c01186
Citations
3
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Glass Fiber Interfaced Special Rolling Circle Amplification for Multiplexed Protein Detection with Paper Strip Digital Readouts

Yingxi Long, Congcong Sun, Siyi Zou, Wu Yuan et al.
3 citations
ACS Sensors
Biosensors and Analytical Detection
2.02
article

Glass Fiber Interfaced Special Rolling Circle Amplification for Multiplexed Protein Detection with Paper Strip Digital Readouts

Yingxi Long, Congcong Sun, Siyi Zou, Wu Yuan, Yu Tian, Guozhen Liu, Sheng Lu, Yun-Wei Yu, Shurui Tao
article en
3 citations

Abstract

Point-of-care testing (POCT) for proteins faces challenges, including limited sensitivity and multiplexing capabilities. The recently developed minimum secondary structured rolling circle amplification (MSS-RCA) promised POCT with desirable sensitivity in nucleic acid detection under isothermal conditions, but with a long assay time. This study integrates the 5' specific enzymatic activity of T7 exonuclease with the high-speed template elongation ability of MSS-RCA in a one-pot system to establish the dual amplification T7-MSSRCA detection platform. T7-MSSRCA employed a specialized reporter modified with human chorionic gonadotrophin (hCG) molecules for signal output on hCG test strips, which could be measured by a lateral flow assay (LFA) analyzer. The integration of T7-MSSRCA with glass fiber interfaced immunoassays enabled multiplexed detection of low-abundance protein targets (α-synuclein, IL-6, TNF-α, and IFN-γ) at subpicogram levels in serum samples of Parkinson's disease with high specificity and accuracy, promising its application in biomarker identification of chronic diseases.

ACS SensorsVol. 10(6)
Chinese University of Hong Kong (HK), Qilu Hospital of Shandong University (CN), University of Hong Kong (HK)
National Natural Science Foundation of China, Shenzhen Bay Laboratory, Guangdong Provincial Pearl River Talents Program, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 14%
Biosensors and Analytical Detection
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.