Use of a Flexible Two-Dimensional Textile Dosimeter with a Kilogray Dose Range to Measure the Dose Distribution for a 60Co Source

The two-dimensional (2D) measurement of radiation dose distribution on non-planar surfaces requires the use of a flexible dosimeter. This work concerns the use of a unique cotton textile-based dosimeter to characterize the dose distribution of a <sup>60</sup>Co source used in the research and sterilization of products. Alternatively, for high-dose-rate experiments, an electron beam accelerator has been used. The dosimeter was prepared by the padding-squeezing-drying of a cotton textile made of cellulose, where a 10% solution of nitrotetrazolium blue chloride (NBT) was used for the padding process. NBT served as a radiation-sensitive compound, which transformed into a purple-brown NBT formazan upon exposure to ionizing radiation. The NBT dosimeter is scanned after irradiation using a flatbed scanner, and the data is processed using dedicated software packages, which together constitute a 2D dose distribution measurement system. The green channel of the RGB color model contributes the most to the color change of the dosimeter. The calibration relation obtained for the green channel showed that the dosimeter responds to doses of 0.8-45 kGy. Conversions of the green channel signal were performed using the calibration relation to analyze the 2D dose at a large distance and close to a <sup>60</sup>Co source shielded by a solid metal and a cylindrical metal structure with holes. Additionally, the dose distribution was assessed using a dosimeter placed on metal implant models undergoing radiation serialization. This work demonstrates the potential of such a dosimeter for characterizing high-dose-rate <sup>60</sup>Co sources and measuring the dose distribution on non-planar surfaces.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-06-06
DOI
https://doi.org/10.3390/ma18122685
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of a Flexible Two-Dimensional Textile Dosimeter with a Kilogray Dose Range to Measure the Dose Distribution for a 60Co Source

Marek Kozicki, Piotr Maras, Radosław Aleksander Wach, Elżbieta Sąsiadek
Materials
Advanced Radiotherapy Techniques
article

Use of a Flexible Two-Dimensional Textile Dosimeter with a Kilogray Dose Range to Measure the Dose Distribution for a 60Co Source

Marek Kozicki, Piotr Maras, Radosław Aleksander Wach, Elżbieta Sąsiadek
article en

Abstract

The two-dimensional (2D) measurement of radiation dose distribution on non-planar surfaces requires the use of a flexible dosimeter. This work concerns the use of a unique cotton textile-based dosimeter to characterize the dose distribution of a <sup>60</sup>Co source used in the research and sterilization of products. Alternatively, for high-dose-rate experiments, an electron beam accelerator has been used. The dosimeter was prepared by the padding-squeezing-drying of a cotton textile made of cellulose, where a 10% solution of nitrotetrazolium blue chloride (NBT) was used for the padding process. NBT served as a radiation-sensitive compound, which transformed into a purple-brown NBT formazan upon exposure to ionizing radiation. The NBT dosimeter is scanned after irradiation using a flatbed scanner, and the data is processed using dedicated software packages, which together constitute a 2D dose distribution measurement system. The green channel of the RGB color model contributes the most to the color change of the dosimeter. The calibration relation obtained for the green channel showed that the dosimeter responds to doses of 0.8-45 kGy. Conversions of the green channel signal were performed using the calibration relation to analyze the 2D dose at a large distance and close to a <sup>60</sup>Co source shielded by a solid metal and a cylindrical metal structure with holes. Additionally, the dose distribution was assessed using a dosimeter placed on metal implant models undergoing radiation serialization. This work demonstrates the potential of such a dosimeter for characterizing high-dose-rate <sup>60</sup>Co sources and measuring the dose distribution on non-planar surfaces.

MaterialsVol. 18(12)
Lodz University of Technology (PL), Copernicus Memorial Hospital (PL)
Openalex Percentile: Top 81%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.