PIFA Sensor for Blood Clotting Detection

This paper presents a dual-band printed inverted-F antenna (PIFA) designed as a biomedical sensor for detecting blood clots in lower limbs. The proposed sensor utilizes the ROGERS RO4003C substrate, chosen for its flexibility, and operates at resonant frequencies of 2.28 GHz and 5.88 GHz, with a compact size of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$35\times 30\ \text{mm}^{2}$</tex>. The primary resonance is attributed to the inverted-F structure of the PIFA, while the secondary resonance arises from the meandered configuration of the PIFA's open arm. Simulation studies are conducted with a leg phantom model that simulates the lower leg structure. Additionally, the sensor's functionality is assessed on freshly cut and corrugated liver tissues to replicate clot formation. The specific absorption rate (SAR) of the sensor is also simulated and measured to ensure safe usage. Analysis of the sensor's reflection coefficient shows significant differences between normal and clotted blood conditions, confirming its potential for reliable clot detection in the specified frequency bands.

Authors

Institutions

Publication Details

Published
2025-05-06
DOI
https://doi.org/10.1109/nrsc65659.2025.11018580
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PIFA Sensor for Blood Clotting Detection

Angie R. Eldamak, Dalia N. Elsheakh, M Sakr, George E. Habib
Advanced Biosensing Techniques and Applications
article

PIFA Sensor for Blood Clotting Detection

Angie R. Eldamak, Dalia N. Elsheakh, M Sakr, George E. Habib
article en

Abstract

This paper presents a dual-band printed inverted-F antenna (PIFA) designed as a biomedical sensor for detecting blood clots in lower limbs. The proposed sensor utilizes the ROGERS RO4003C substrate, chosen for its flexibility, and operates at resonant frequencies of 2.28 GHz and 5.88 GHz, with a compact size of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$35\times 30\ \text{mm}^{2}$</tex>. The primary resonance is attributed to the inverted-F structure of the PIFA, while the secondary resonance arises from the meandered configuration of the PIFA's open arm. Simulation studies are conducted with a leg phantom model that simulates the lower leg structure. Additionally, the sensor's functionality is assessed on freshly cut and corrugated liver tissues to replicate clot formation. The specific absorption rate (SAR) of the sensor is also simulated and measured to ensure safe usage. Analysis of the sensor's reflection coefficient shows significant differences between normal and clotted blood conditions, confirming its potential for reliable clot detection in the specified frequency bands.

Ain Shams University (EG), Badr University in Cairo (EG)
Zero hunger
Openalex Percentile: Top 88%
Advanced Biosensing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.