Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs

Emerging handheld and wearable ultrasound devices enable diagnosis and long-term monitoring outside clinical settings. They require a low-power, highly complex, locally integrated system to process the RF data. The analog-to-digital converter (ADC) is a critical building block in the receive chain of these systems as it enables digital beamforming and image reconstruction. However, the ADCs currently used in cart-based imaging systems are bulky and consume too much power to be integrated into battery-powered devices. This article investigates how the area and power consumption of the commonly used successive approximation register (SAR) ADC can be reduced without negatively affecting B-mode and color-Doppler image quality. A Monte Carlo (MC) simulation study was performed in which RF data acquired with a phased-array transducer in Field II were digitized using a model of a nonideal ADC. Five different nonidealities were applied to four commonly used SAR-ADC architectures. B-mode and color-Doppler images were reconstructed from the digitized RF data. The impact of the nonidealities on the image quality was evaluated by means of three image quality metrics (IQM): peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and contrast-to-noise ratio (CNR). The effectiveness of error correction and ways of calibration are also discussed. The results show that both B-mode imaging and color-Doppler imaging are inherently resilient to nonidealities, particularly capacitor mismatch, leading to relaxed ADC requirements and paving the way for more practical in-probe digitization.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-06-06
DOI
https://doi.org/10.1109/tuffc.2025.3577258
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs

Michiel A. P. Pertijs, Nikola Radeljic-Jakic, Hendrik J. Vos, Nuriel N. M. Rozsa et al.
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Ultrasound Imaging and Elastography
article

Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs

Michiel A. P. Pertijs, Nikola Radeljic-Jakic, Hendrik J. Vos, Nuriel N. M. Rozsa, Adriaan J. Flikweert
article en

Abstract

Emerging handheld and wearable ultrasound devices enable diagnosis and long-term monitoring outside clinical settings. They require a low-power, highly complex, locally integrated system to process the RF data. The analog-to-digital converter (ADC) is a critical building block in the receive chain of these systems as it enables digital beamforming and image reconstruction. However, the ADCs currently used in cart-based imaging systems are bulky and consume too much power to be integrated into battery-powered devices. This article investigates how the area and power consumption of the commonly used successive approximation register (SAR) ADC can be reduced without negatively affecting B-mode and color-Doppler image quality. A Monte Carlo (MC) simulation study was performed in which RF data acquired with a phased-array transducer in Field II were digitized using a model of a nonideal ADC. Five different nonidealities were applied to four commonly used SAR-ADC architectures. B-mode and color-Doppler images were reconstructed from the digitized RF data. The impact of the nonidealities on the image quality was evaluated by means of three image quality metrics (IQM): peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and contrast-to-noise ratio (CNR). The effectiveness of error correction and ways of calibration are also discussed. The results show that both B-mode imaging and color-Doppler imaging are inherently resilient to nonidealities, particularly capacitor mismatch, leading to relaxed ADC requirements and paving the way for more practical in-probe digitization.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(8)
Delft University of Technology (NL)
Industry, innovation and infrastructure
Openalex Percentile: Top 80%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs — Michiel A. P. Pertijs, Nikola Radeljic-Jakic, et al. · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control (2025) | TGRS Research Map | TGRS