Extreme accuracy of the autocollimator-null-indicator

Improving the accuracy of measurements in dynamic goniometry is inextricably linked with achieving the ultimate accuracy of the optical null indicator. This device is part of angle measuring devices operating on the principle of a dynamic goniometer. The autocollimator-null-indicator, when its optical axis coincides with the normal to the controlled reflecting surface, generates an electric pulse, which is used to read the readings of the angular scale of the dynamic goniometer. The ultimate accuracy of the autocollimator-null-indicator is determined by its random error. The random error of measurements of the constant angular position of a reflecting mirror at different times of the day was experimentally studied. It is shown that external noises prevail during daytime measurements – various vibrations, air and external lighting fluctuations, which depend on the distance between the autocollimator-null-indicator and the mirror, and during nighttime measurements the influence of external effects on the measurement results is minimal, which made it possible to obtain the measurement error at night at the flicker noise level. The experimental data are analyzed using the methods of mathematical statistics, Allan variance and wavelet analysis. It is determined that the arrays of random variables characterizing the random error are non-stationary. The minimum value of the random error of the autocollimator-null-indicator was 0.001″. The presented results are of interest to specialists developing and using optoelectronic devices based on the autocollimator.

Authors

Institutions

Publication Details

Journal
Izmeritel`naya Tekhnika
Published
2025-06-06
DOI
https://doi.org/10.32446/0368-1025it.2025-2-64-69
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extreme accuracy of the autocollimator-null-indicator

Roman A. Larichev, P. A. Pavlov, E. M. Ivashchenko
Izmeritel`naya Tekhnika
Calibration and Measurement Techniques
article

Extreme accuracy of the autocollimator-null-indicator

Roman A. Larichev, P. A. Pavlov, E. M. Ivashchenko
article en

Abstract

Improving the accuracy of measurements in dynamic goniometry is inextricably linked with achieving the ultimate accuracy of the optical null indicator. This device is part of angle measuring devices operating on the principle of a dynamic goniometer. The autocollimator-null-indicator, when its optical axis coincides with the normal to the controlled reflecting surface, generates an electric pulse, which is used to read the readings of the angular scale of the dynamic goniometer. The ultimate accuracy of the autocollimator-null-indicator is determined by its random error. The random error of measurements of the constant angular position of a reflecting mirror at different times of the day was experimentally studied. It is shown that external noises prevail during daytime measurements – various vibrations, air and external lighting fluctuations, which depend on the distance between the autocollimator-null-indicator and the mirror, and during nighttime measurements the influence of external effects on the measurement results is minimal, which made it possible to obtain the measurement error at night at the flicker noise level. The experimental data are analyzed using the methods of mathematical statistics, Allan variance and wavelet analysis. It is determined that the arrays of random variables characterizing the random error are non-stationary. The minimum value of the random error of the autocollimator-null-indicator was 0.001″. The presented results are of interest to specialists developing and using optoelectronic devices based on the autocollimator.

Izmeritel`naya TekhnikaVol. 74(2)
Saint Petersburg State Electrotechnical University (RU)
Openalex Percentile: Top 83%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.