Effects of implant abutment CAD/CAM design parameters on subgingival remnant cement
Within the limitations of this study, a smaller margin curvature radius, smaller convergence angle, and straight subgingival shape were associated with reduced RCS length, surface area, and weight.
Authors
- Ki-Sun Lee (ORCID: https://orcid.org/0000-0002-6933-3589)
- Jae‐Jun Ryu (ORCID: https://orcid.org/0000-0001-6903-5955)
- Ji Hong Min
- Jeong‐Yol Lee (ORCID: https://orcid.org/0000-0003-3079-0376)
- Ji Suk Shim (ORCID: https://orcid.org/0000-0002-4112-6051)
- Oh Hwiseong
- Fanghui Ji
Institutions
- Korea University (KR)
- Korea University Medical Center (KR)
- Ansan University (KR)
- Korea University (JP)
Publication Details
- Journal
- Journal of Prosthodontic Research
- Published
- 2025-06-06
- DOI
- https://doi.org/10.2186/jpr.jpr_d_24_00304
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Research Foundation
- Ministry of Education
- National Research Foundation of Korea