Characterizing and exploiting cross-talk effect in SPAD arrays for two-photon interference

SPAD arrays are becoming a popular choice for measuring two-photon interference effects thanks to their high timing precision, fast readout, and high quantum efficiency. However, such sensors are affected by cross-talk that may mimic the useful signal. Even with a low probability of seeing cross-talk effect between neighboring SPADs, it was found that it still may reach the farther channels up to a half of millimeter away. Moreover, the use of microlenses that help SPADs achieve even better efficiency further boosts the cross-talk effect. In this work, we characterize the cross-talk effect and compare it to the Hanbury Brown-Twiss effect in the LinoSPAD2 camera, which has a linear sensor of 512 SPADs. Additionally, we compare the results between sensors with and without the microlenses. Finally, we present a timing calibration technique for the detector that utilizes the cross-talk effect.

Authors

Institutions

Publication Details

Published
2025-06-06
DOI
https://doi.org/10.1117/12.3058261
Primary Topic
Advanced Photonic Communication Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterizing and exploiting cross-talk effect in SPAD arrays for two-photon interference

Tommaso Milanese, Edoardo Charbon, P. Švihra, Ermanno Bernasconi et al.
Advanced Photonic Communication Systems
article

Characterizing and exploiting cross-talk effect in SPAD arrays for two-photon interference

Tommaso Milanese, Edoardo Charbon, P. Švihra, Ermanno Bernasconi, Claudio Bruschini, Ondřej Matoušek, Leonel Sousa, Sergei Kulkov, A. Nomerotski, Lada Radmacherova
article en

Abstract

SPAD arrays are becoming a popular choice for measuring two-photon interference effects thanks to their high timing precision, fast readout, and high quantum efficiency. However, such sensors are affected by cross-talk that may mimic the useful signal. Even with a low probability of seeing cross-talk effect between neighboring SPADs, it was found that it still may reach the farther channels up to a half of millimeter away. Moreover, the use of microlenses that help SPADs achieve even better efficiency further boosts the cross-talk effect. In this work, we characterize the cross-talk effect and compare it to the Hanbury Brown-Twiss effect in the LinoSPAD2 camera, which has a linear sensor of 512 SPADs. Additionally, we compare the results between sensors with and without the microlenses. Finally, we present a timing calibration technique for the detector that utilizes the cross-talk effect.

Florida International University (US), FZU ‒ Institute of Physics of the Academy of Sciences of the Czech Republic (CZ), Czech Technical University in Prague (CZ), École Polytechnique Fédérale de Lausanne (CH)
Openalex Percentile: Top 89%
Advanced Photonic Communication Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterizing and exploiting cross-talk effect in SPAD arrays for two-photon interference — Tommaso Milanese, Edoardo Charbon, et al. · (2025) | TGRS Research Map | TGRS