Influence of temperature and uniaxial loading on the performance of the embedded intelligent sensing elements (EISE) in cement-based materials

This study investigates the effect of the temperature in a novel embedded intelligent sensing element (EISE) applied in cement-based materials hydration monitoring, and the stability of the signal obtained from EISE after the cement hydration at high temperature and uniaxial compressive test is also characterized. The proposed EISE can evaluate signal stability and surrounding material conditions. Experiments involve signal acquisition using EISE in water at different temperatures, continuous hydration monitoring of ordinary Portland and sulfoaluminate cements, and comparison of signals obtained from EISE before being embedded in sulphoaluminate cement samples and after the EISE has suffered the uniaxial loading and complete removal from the cement. Results show that the temperature variation of water can significantly affect the signal. Stable direct waves during the ordinary Portland cement hydration are characterized. However, sulfoaluminate cement with high exothermic rates (up to 59.6 °C gradient) triggers signal disruptions within 400 minutes, including waveform anomalies and energy fluctuations. The direct waves recover upon cooling, implying reversible thermal impacts. Comparisons of the signals obtained by the EISE before being embedded in cement and after uniaxial compression of the cement sample embedded with the EISE reveal local deformations through the change of coda waves, but the direct waves maintain the same waveforms. Overall, the EISE proves durable for continuous monitoring, effectively identifying temperature- and load-induced disturbances. • EISE enables independent temperature monitoring. • Prolonged high temperature affects EISE signal quantification. • EISE verifies signal reversibility via direct waves at high temperature and load.

Authors

Institutions

Publication Details

Journal
Case Studies in Construction Materials
Published
2025-06-06
DOI
https://doi.org/10.1016/j.cscm.2025.e04883
Citations
2
Primary Topic
Smart Materials for Construction
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of temperature and uniaxial loading on the performance of the embedded intelligent sensing elements (EISE) in cement-based materials

Jie Yao, Zhuo Xu, Weijian Ding, Wenjie Zhang et al.
2 citations
Case Studies in Construction Materials
Smart Materials for Construction
1.01
article

Influence of temperature and uniaxial loading on the performance of the embedded intelligent sensing elements (EISE) in cement-based materials

Jie Yao, Zhuo Xu, Weijian Ding, Wenjie Zhang, Ming Sun, Yuanxing Wang, Xia Wang, Weiwei Xu, Shijie Wang
article en
2 citations

Abstract

This study investigates the effect of the temperature in a novel embedded intelligent sensing element (EISE) applied in cement-based materials hydration monitoring, and the stability of the signal obtained from EISE after the cement hydration at high temperature and uniaxial compressive test is also characterized. The proposed EISE can evaluate signal stability and surrounding material conditions. Experiments involve signal acquisition using EISE in water at different temperatures, continuous hydration monitoring of ordinary Portland and sulfoaluminate cements, and comparison of signals obtained from EISE before being embedded in sulphoaluminate cement samples and after the EISE has suffered the uniaxial loading and complete removal from the cement. Results show that the temperature variation of water can significantly affect the signal. Stable direct waves during the ordinary Portland cement hydration are characterized. However, sulfoaluminate cement with high exothermic rates (up to 59.6 °C gradient) triggers signal disruptions within 400 minutes, including waveform anomalies and energy fluctuations. The direct waves recover upon cooling, implying reversible thermal impacts. Comparisons of the signals obtained by the EISE before being embedded in cement and after uniaxial compression of the cement sample embedded with the EISE reveal local deformations through the change of coda waves, but the direct waves maintain the same waveforms. Overall, the EISE proves durable for continuous monitoring, effectively identifying temperature- and load-induced disturbances. • EISE enables independent temperature monitoring. • Prolonged high temperature affects EISE signal quantification. • EISE verifies signal reversibility via direct waves at high temperature and load.

Case Studies in Construction MaterialsVol. 22
Shenzhen Institute of Information Technology (CN), Shenzhen Polytechnic University (CN), University of Jinan (CN), China State Construction Engineering (China) (CN)
National Natural Science Foundation of China, China Scholarship Council
Openalex Percentile: Top 26%
Smart Materials for Construction
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.