District cooling optimal operation to decarbonize urban cold energy supply

• District Cooling Systems are gaining attention as decarbonization energy solutions. • Optimal operation of District Cooling is crucial for cost ownership. • Levelized Cost Of Cold Energy has been introduced to compare different layouts. • Cogeneration integration in District Cooling gives primary energy savings and avoided emissions. • Master Planning and Optimal Dispatch bring lower capital and maintenance costs. District Energy Systems have seen growing attention for heat supply while, for meeting the cooling demand still, the applications are limited to tropical Countries. Given that, the deployment of district cooling systems has still many barriers, requires detailed planning and related dispatch to be found convenient in contexts with few applications already set. In this paper, the authors investigate the role of alternative district cooling plant layouts that include Combined Heat & Power equipment’s to meet a cooling demand. If, on the one hand, the increase of the District Cooling Plant layout complexity increases the investment costs, on the other hand, the reduction of the primary energy consumption makes this alternative attractive and of interest, especially for large capacity. By introducing the Levelized Cost of Cold Energy, the equivalent cost for 1 kWh of cold energy is of about 0.011€ in the baseline scenario, while for the best-optimized layout decreases to 0.09 €. Aside from the economic investigation, the optimisation procedure identified that a system made up of two twin cogeneration units (3 MWe internal combustion engine) and 3.3 MWc absorption chiller leads to 12% reduction of carbon emissions compared to the baseline, together with 0.5 million € saving, accounting for a carbon tax rate of 100 €/ton.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2025-06-06
DOI
https://doi.org/10.1016/j.enconman.2025.120019
Citations
2
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

District cooling optimal operation to decarbonize urban cold energy supply

Benedetto Nastasi, Stefano Mazzoni
2 citations
Energy Conversion and Management
Integrated Energy Systems Optimization
1.46
article

District cooling optimal operation to decarbonize urban cold energy supply

Benedetto Nastasi, Stefano Mazzoni
article en
2 citations

Abstract

• District Cooling Systems are gaining attention as decarbonization energy solutions. • Optimal operation of District Cooling is crucial for cost ownership. • Levelized Cost Of Cold Energy has been introduced to compare different layouts. • Cogeneration integration in District Cooling gives primary energy savings and avoided emissions. • Master Planning and Optimal Dispatch bring lower capital and maintenance costs. District Energy Systems have seen growing attention for heat supply while, for meeting the cooling demand still, the applications are limited to tropical Countries. Given that, the deployment of district cooling systems has still many barriers, requires detailed planning and related dispatch to be found convenient in contexts with few applications already set. In this paper, the authors investigate the role of alternative district cooling plant layouts that include Combined Heat & Power equipment’s to meet a cooling demand. If, on the one hand, the increase of the District Cooling Plant layout complexity increases the investment costs, on the other hand, the reduction of the primary energy consumption makes this alternative attractive and of interest, especially for large capacity. By introducing the Levelized Cost of Cold Energy, the equivalent cost for 1 kWh of cold energy is of about 0.011€ in the baseline scenario, while for the best-optimized layout decreases to 0.09 €. Aside from the economic investigation, the optimisation procedure identified that a system made up of two twin cogeneration units (3 MWe internal combustion engine) and 3.3 MWc absorption chiller leads to 12% reduction of carbon emissions compared to the baseline, together with 0.5 million € saving, accounting for a carbon tax rate of 100 €/ton.

Energy Conversion and ManagementVol. 341
University of Rome Tor Vergata (IT)
Openalex Percentile: Top 17%
Integrated Energy Systems Optimization
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.