Comparison Of Transfer Accuracy Among Hexed Implant Mounts, Clips Impression Copings, And Open-Tray Impression Copings at Different Implant Angulations: An In Vitro Study
Open-tray and clips impression copings provide reliable implant position transfer for straight and angulated implants up to 25°. The hexed implant mount is accurate up to 15° angulation but shows increased deviations at 25°.
Authors
- Rana A Negm
- Mohamed Seif (ORCID: https://orcid.org/0000-0002-0131-0030)
- Hassan Mohamed Abouelkheir (ORCID: https://orcid.org/0000-0003-4159-3837)
- Ahmed Adel Abdel Hakim (ORCID: https://orcid.org/0000-0002-5926-7194)
Institutions
- Alexandria University (EG)
Publication Details
- Journal
- BMC Oral Health
- Published
- 2025-06-06
- DOI
- https://doi.org/10.1186/s12903-025-06304-8
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Science and Technology Development Fund
- Alexandria University