Prosedur Pemeriksaan CT Scan Kepala Polos pada Kasus Microcephaly di Instalasi Radiologi RS Roemani Muhammadiyah Semarang

Microcephaly is a condition in which a child's head circumference is smaller than the average for age and gender. The diagnosis can be made using a CT Scan, which should be adjusted to the patient's age according to the IAEA protocol (2012), with an ideal effective dose of 1.8–3.8 mSv for a tube current of 200 mAs. However, at the Radiology Installation of Roemani Muhammadiyah Hospital Semarang, the examination was carried out without differentiating age, resulting in an excess dose of 9.317 mSv. This study aims to evaluate the procedures, diagnostic information, and radiation protection in plain head CT Scans of pediatric patients with microcephaly. This study used a qualitative approach through observation, interviews, and documentation of 3 radiographers, 1 PPR, and 1 radiologist. The results showed no protection for patients and only basic protection for companions. CT Scans showed decreased brain volume and ventriculomegaly. It is recommended that the CT Scan protocol be adjusted to the child's age to reduce the radiation dose, through the setting of exposure factors, slice thickness, and pitch.

Authors

Institutions

Publication Details

Journal
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Published
2025-05-26
DOI
https://doi.org/10.55606/jikki.v5i2.6074
Primary Topic
Geological and Geophysical Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prosedur Pemeriksaan CT Scan Kepala Polos pada Kasus Microcephaly di Instalasi Radiologi RS Roemani Muhammadiyah Semarang

Ike Ade Nur Liscyaningsih, Sofie Nornalita Dewi, Shintanaya Anggraeni
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Geological and Geophysical Studies
article

Prosedur Pemeriksaan CT Scan Kepala Polos pada Kasus Microcephaly di Instalasi Radiologi RS Roemani Muhammadiyah Semarang

Ike Ade Nur Liscyaningsih, Sofie Nornalita Dewi, Shintanaya Anggraeni
article en

Abstract

Microcephaly is a condition in which a child's head circumference is smaller than the average for age and gender. The diagnosis can be made using a CT Scan, which should be adjusted to the patient's age according to the IAEA protocol (2012), with an ideal effective dose of 1.8–3.8 mSv for a tube current of 200 mAs. However, at the Radiology Installation of Roemani Muhammadiyah Hospital Semarang, the examination was carried out without differentiating age, resulting in an excess dose of 9.317 mSv. This study aims to evaluate the procedures, diagnostic information, and radiation protection in plain head CT Scans of pediatric patients with microcephaly. This study used a qualitative approach through observation, interviews, and documentation of 3 radiographers, 1 PPR, and 1 radiologist. The results showed no protection for patients and only basic protection for companions. CT Scans showed decreased brain volume and ventriculomegaly. It is recommended that the CT Scan protocol be adjusted to the child's age to reduce the radiation dose, through the setting of exposure factors, slice thickness, and pitch.

Jurnal Ilmu Kedokteran dan Kesehatan IndonesiaVol. 5(2)
Universitas 'Aisyiyah Yogyakarta
Openalex Percentile: Top 82%
Geological and Geophysical Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.