Comparison of Operative Outcomes of Open Thyroidectomy with Electrothermal Bipolar Vessel Sealer versus Conventional Hemostasis for Benign Thyroid Swelling in Adults Population

Precise dissection and effective hemostasis are crucial for safe thyroid surgery. The bipolar vessel sealer, a first-generation electrosurgical instrument, is widely used in thyroidectomies to improve hemostasis, reduce tissue trauma, shorten surgery time, and eliminate the need for sutures. Objective: To compare the operative outcomes of electrothermal bipolar vessel sealer in total thyroidectomy. Methods: At the Department of Surgery, Sir Ganga Ram Hospital, from August 2024 to January 2025, a quasi-experimental study was carried out, involving 80 patients undergoing total thyroidectomy. Exclusion criteria included patients with significant comorbidities, bleeding disorders, or renal and liver dysfunctions. The study participants were divided into two groups: Group A (bipolar vessel sealer) and Group B (clamp-and-tie technique). Primary outcomes included surgery duration, intraoperative blood loss, and hospital stay. Data were entered and analyzed by SPSS version 25.0. Results: The average age of patients was 35.5 ± 4.9 years. Group A had 70% female and 30% male, while Group B had 77.5% female and 22.5% male. Group A had significantly shorter hospital stays (3.8 ± 1.2 days) compared to Group B (5.2 ± 2.3 days, p=0.000). Intraoperative blood loss was significantly lower in Group A (109.7 ± 7.3 mL) compared to Group B (154.3 ± 6.7 mL, p<0.000). Surgery duration was longer in Group A (121.3 ± 13.1 minutes) than in Group B (94.3 ± 11.3 minutes, p<0.05). Conclusions: It was concluded that the bipolar vessel sealer in total thyroidectomy for benign thyroid swelling is effective, and results in shorter hospital stays without increasing complications or costs.

Authors

Institutions

Publication Details

Journal
Pakistan Journal of Health Sciences
Published
2025-05-31
DOI
https://doi.org/10.54393/pjhs.v6i5.3044
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Operative Outcomes of Open Thyroidectomy with Electrothermal Bipolar Vessel Sealer versus Conventional Hemostasis for Benign Thyroid Swelling in Adults Population

Sharon Zahra, Sheryar Afzal, Ghazala Bano, Mehwish Raheem et al.
Pakistan Journal of Health Sciences
Thyroid and Parathyroid Surgery
article

Comparison of Operative Outcomes of Open Thyroidectomy with Electrothermal Bipolar Vessel Sealer versus Conventional Hemostasis for Benign Thyroid Swelling in Adults Population

Sharon Zahra, Sheryar Afzal, Ghazala Bano, Mehwish Raheem, Absar Nazir, Tahira Jamil, Muhammad Usman, Mohammad Amir Jan, Mujahid Islam
article en

Abstract

Precise dissection and effective hemostasis are crucial for safe thyroid surgery. The bipolar vessel sealer, a first-generation electrosurgical instrument, is widely used in thyroidectomies to improve hemostasis, reduce tissue trauma, shorten surgery time, and eliminate the need for sutures. Objective: To compare the operative outcomes of electrothermal bipolar vessel sealer in total thyroidectomy. Methods: At the Department of Surgery, Sir Ganga Ram Hospital, from August 2024 to January 2025, a quasi-experimental study was carried out, involving 80 patients undergoing total thyroidectomy. Exclusion criteria included patients with significant comorbidities, bleeding disorders, or renal and liver dysfunctions. The study participants were divided into two groups: Group A (bipolar vessel sealer) and Group B (clamp-and-tie technique). Primary outcomes included surgery duration, intraoperative blood loss, and hospital stay. Data were entered and analyzed by SPSS version 25.0. Results: The average age of patients was 35.5 ± 4.9 years. Group A had 70% female and 30% male, while Group B had 77.5% female and 22.5% male. Group A had significantly shorter hospital stays (3.8 ± 1.2 days) compared to Group B (5.2 ± 2.3 days, p=0.000). Intraoperative blood loss was significantly lower in Group A (109.7 ± 7.3 mL) compared to Group B (154.3 ± 6.7 mL, p<0.000). Surgery duration was longer in Group A (121.3 ± 13.1 minutes) than in Group B (94.3 ± 11.3 minutes, p<0.05). Conclusions: It was concluded that the bipolar vessel sealer in total thyroidectomy for benign thyroid swelling is effective, and results in shorter hospital stays without increasing complications or costs.

Pakistan Journal of Health Sciences
Fatima Jinnah Medical University (PK)
Openalex Percentile: Top 78%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.