Preliminary results of one-stage repair of residual aortic dissection using dense mesh stent combined with release and post-processing techniques

ObjectiveThis study aims to preliminarily evaluate the early safety and efficacy of one-stage repair of residual aortic dissection using dense metal mesh stents combined with improved release and post-processing techniques.MethodsA prospective, single-center, single-arm clinical trial was designed and implemented, enrolling patients with residual aortic dissection to undergo metal mesh stent implantation under guidance of stent release and post-processing techniques. Patients received aortic CTA follow-up at 30 days post-surgery to assess early safety and efficacy.ResultsA total of 25 patients were enrolled, 14 in the (sub)acute phase and 11 in the chronic phase. No postoperative deaths, reinterventions, or aortic-related adverse events like malperfusion or ischemia were reported. The immediate technical success rate was 100%. For (sub)acute cases, the true lumen volume increased by 176.10%, while the false lumen decreased by 83.95%. False lumen thrombosis was grade II in two patients (14.29%), grade III in seven (50.00%), and grade IV in five (35.71%). For chronic cases, the true lumen volume increased by 96.92%, while the false lumen decreased by 73.43%. Thrombosis was grade II in three patients (27.27%), grade III in five (45.45%), and grade IV in three (27.27%). Postoperative aortic CTA showed that all visceral artery branches remained patent, and high-risk ischemic branches were converted to non-high-risk.ConclusionsPreliminary results suggest that dense mesh stents combined with release and post-processing techniques have acceptable early safety and efficacy. For acute and chronic residual aortic dissection patients with visceral artery branch involvement, this method may offer an alternative treatment option. Registration no. ChiCTR2200055277.

Authors

Institutions

Publication Details

Journal
Science Progress
Published
2025-04-01
DOI
https://doi.org/10.1177/00368504251340800
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary results of one-stage repair of residual aortic dissection using dense mesh stent combined with release and post-processing techniques

S.-N. Li, Yongmin Liu, Huanyu Qiao, Cheng Zhang et al.
Science Progress
Aortic Disease and Treatment Approaches
article

Preliminary results of one-stage repair of residual aortic dissection using dense mesh stent combined with release and post-processing techniques

S.-N. Li, Yongmin Liu, Huanyu Qiao, Cheng Zhang, Tao Bai, Bo Yang, Honglei Zhao, Chen Zhang, Hongbo Zhang, Kefeng Zhang, Xiaohai Ma
article en

Abstract

ObjectiveThis study aims to preliminarily evaluate the early safety and efficacy of one-stage repair of residual aortic dissection using dense metal mesh stents combined with improved release and post-processing techniques.MethodsA prospective, single-center, single-arm clinical trial was designed and implemented, enrolling patients with residual aortic dissection to undergo metal mesh stent implantation under guidance of stent release and post-processing techniques. Patients received aortic CTA follow-up at 30 days post-surgery to assess early safety and efficacy.ResultsA total of 25 patients were enrolled, 14 in the (sub)acute phase and 11 in the chronic phase. No postoperative deaths, reinterventions, or aortic-related adverse events like malperfusion or ischemia were reported. The immediate technical success rate was 100%. For (sub)acute cases, the true lumen volume increased by 176.10%, while the false lumen decreased by 83.95%. False lumen thrombosis was grade II in two patients (14.29%), grade III in seven (50.00%), and grade IV in five (35.71%). For chronic cases, the true lumen volume increased by 96.92%, while the false lumen decreased by 73.43%. Thrombosis was grade II in three patients (27.27%), grade III in five (45.45%), and grade IV in three (27.27%). Postoperative aortic CTA showed that all visceral artery branches remained patent, and high-risk ischemic branches were converted to non-high-risk.ConclusionsPreliminary results suggest that dense mesh stents combined with release and post-processing techniques have acceptable early safety and efficacy. For acute and chronic residual aortic dissection patients with visceral artery branch involvement, this method may offer an alternative treatment option. Registration no. ChiCTR2200055277.

Science ProgressVol. 108(2)
Capital Medical University (CN), Beijing Anzhen Hospital (CN)
Beijing Municipal Science and Technology Commission
Good health and well-being
Openalex Percentile: Top 78%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.